The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Four-Electron O2-Electroreduction Biocatalyst Superior to Platinum and a Biofuel Cell Operating at 0.88 V
Abstract
O2 was electroreduced to water, at a true-surface-area-based current density of 0.5 mA cm-2, at 37 degrees C and at pH 5 on a "wired" laccase bioelectrocatalyst-coated carbon fiber cathode. The polarization (potential vs the reversible potential of the O2 /H2O half-cell in the same electrolyte) of the cathode was only -0.07 V, approximately one-fifth of the -0.37 V polarization of a smooth platinum fiber cathode, operating in its optimal electrolyte, 0.5 M H2SO4. The bioelectrocatalyst was formed by "wiring" laccase to carbon through an electron conducting redox hydrogel, its redox functions tethered through long and flexible spacers to its cross-linked and hydrated polymer. Incorporation of the tethers increased the apparent electron diffusion coefficient 100-fold to (7.6 +/- 0.3) x 10-7 cm 2 s-1. A miniature single-compartment glucose-O2 biofuel cell made with the novel cathode operated optimally at 0.88 V, the highest operating voltage for a compartmentless miniature fuel cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Self-citationChen, T., Barton, S. C., Binyamin, G., Gao, Z., Zhang, Y., Kim, H.-H., & Heller, A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0163164 · Cited by 427
Self-citationMano, N., Fernandez, J. L., Kim, Y., Shin, W., Bard, A. J., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja038285d · Cited by 204
Self-citationZakeeruddin, S. M., Fraser, D. M., Nazeeruddin, M.-K., & Grätzel, M. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80542-c · Cited by 179
Neergat, M., Shukla, A. K., & Gandhi, K. S. (2001) · Journal of Applied Electrochemistry · doi:10.1023/a:1017575918643 · Cited by 168
Cited by
A review on non-precious metal electrocatalysts for PEM fuel cells
Chen, Z., Higgins, D., Yu, A., Zhang, L., & Zhang, J. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00558d · Cited by 1,832
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationBankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,253
Biofuel cells and their development
Bullen, R. A., Arnot, T. C., Lakeman, J. B., & Walsh, F. C. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.030 · Cited by 1,011
Electroreduction of Dioxygen for Fuel-Cell Applications: Materials and Challenges
Gewirth, A. A., & Thorum, M. S. (2010) · Inorganic Chemistry · doi:10.1021/ic9022486 · Cited by 705
Biofuel cells—Recent advances and applications
Davis, F., & Higson, S. P. J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.04.029 · Cited by 591
Microfluidic fuel cells: A review
Kjeang, E., Djilali, N., & Sinton, D. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.10.011 · Cited by 578
Challenges in biocatalysis for enzyme-based biofuel cells
Kim, J., Jia, H., & Wang, P. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.11.006 · Cited by 554
Implanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Enzymatic fuel cells: Recent progress
Leech, D., Kavanagh, P., & Schuhmann, W. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.02.087 · Cited by 446
A Glucose BioFuel Cell Implanted in Rats
Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F., Alcaraz, J.-P., Gorgy, K., Lenouvel, F., Mathé, S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010476 · Cited by 413
Harnisch, F., & Schröder, U. (2010) · Chemical Society Reviews · doi:10.1039/c003068f · Cited by 388
Electron-conducting redox hydrogels: design, characteristics and synthesis
Heller, A. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.09.018 · Cited by 352
Self-citationExtended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Self-citationFrom “cyborg” lobsters to a pacemaker powered by implantable biofuel cells
MacVittie, K., Halámek, J., Halámková, L., Southcott, M., Jemison, W. D., Lobel, R., & Katz, E. (2013) · Energy Environ. Sci. · doi:10.1039/c2ee23209j · Cited by 332
Nanostructured material-based biofuel cells: recent advances and future prospects
Zhao, C.-E., Gai, P., Song, R., Chen, Y., Zhang, J., & Zhu, J.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00044d · Cited by 324
Glucose oxidase anode for biofuel cell based on direct electron transfer
Ivnitski, D., Branch, B., Atanassov, P., & Apblett, C. (2006) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.05.024 · Cited by 291
Designer laccases: a vogue for high-potential fungal enzymes?
Rodgers, C. J., Blanford, C. F., Giddens, S. R., Skamnioti, P., Armstrong, F. A., & Gurr, S. J. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.11.001 · Cited by 276
Living battery – biofuel cells operating in vivo in clams
Szczupak, A., Halámek, J., Halámková, L., Bocharova, V., Alfonta, L., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21626d · Cited by 259
Metadata
- Authors
- Soukharev, V., Mano, N., & Heller, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-06-17
- Volume
- 126
- Issue
- 27
- Pages
- 8368-8369
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2026853932
- Cited by
- 310
- References
- 5
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.