The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Selective Functionalization of In2O3 Nanowire Mat Devices for Biosensing Applications
Abstract
A strategy to covalently attach biological molecules to the electrochemically active surface of indium oxide nanowire (In2O3 NW) mat devices is presented. A self-assembled monolayer (SAM) of 4-(1,4-dihydroxybenzene)butyl phosphonic acid (HQ-PA) was generated on an indium tin oxide (ITO)-coated glass and In2O3 NWs surface. The chemical steps required for surface derivatization were optimized on an ITO surface prior to modifying the In2O3 NWs. The hydroquinone group contained in the HQ-PA SAM was electrochemically oxidized to quinone (Q-PA) at +330 mV. The monolayer of Q-PA was allowed to react with a thiol-terminated DNA. The DNA was paired to its complementary strand tagged with a fluorescence dye. Attachment of DNA was verified using fluorescence microscopy. A device was subsequently prepared on a SiO2-supported mat of In2O3 NWs by depositing gold electrodes on the mat surface. The reaction strategy optimized on ITO was applied to this In2O3 NW-based device. Arrays of In2O3 NWs on a single substrate were electrochemically activated in a selective manner to Q-PA. Activated In2O3 NWs underwent reaction with HS-DNA and gave a positive fluorescence response after pairing with the dye-DNA. The unactivated In2O3 NWs gave no response, thus demonstrating selective functionalization of an In2O3 NW array. This can be considered a key step for the future fabrication of large-scale, inexpensive, nanoscale biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Alternative Plasmonic Materials: Beyond Gold and Silver
Naik, G. V., Shalaev, V. M., & Boltasseva, A. (2013) · Advanced Materials · doi:10.1002/adma.201205076 · Cited by 2,373
Aptamer–field-effect transistors overcome Debye length limitations for small-molecule sensing
Nakatsuka, N., Yang, K.-A., Abendroth, J. M., Cheung, K. M., Xu, X., Yang, H., Zhao, C., Zhu, B., Rim, Y. S., Yang, Y., et al. (2018) · Science · doi:10.1126/science.aao6750 · Cited by 951
Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Label-free detection of DNA hybridization using carbon nanotube network field-effect transistors
Star, A., Tu, E., Niemann, J., Gabriel, J.-C. P., Joiner, C. S., & Valcke, C. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504146103 · Cited by 670
Chemical sensors based on nanostructured materials
Huang, X.-J., & Choi, Y.-K. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.06.022 · Cited by 662
Metadata
- Authors
- Curreli, M., Li, C., Sun, Y., Lei, B., Gundersen, M. A., Thompson, M. E., & Zhou, C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-04-26
- Volume
- 127
- Issue
- 19
- Pages
- 6922-6923
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2036472236
- Cited by
- 240
- References
- 1
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Functionalization of In2O3 Nanowire Mat Devices for Biosensing Applications. https://app.cochat.ai/papers/10.1021/ja0503478
- The paper
- Curreli, M., Li, C., Sun, Y., Lei, B., Gundersen, M. A., Thompson, M. E., & Zhou, C. (2005). Selective Functionalization of In2O3 Nanowire Mat Devices for Biosensing Applications. Journal of the American Chemical Society. https://doi.org/10.1021/ja0503478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.