The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Generation of Superparamagnetic Liposomes Revealed as Highly Efficient MRI Contrast Agents for in Vivo Imaging
Abstract
Maghemite (gamma-Fe2O3) nanocrystals stable at neutral pH and in isotonic aqueous media were synthesized and encapsulated within large unilamellar vesicles of egg phosphatidylcholine (EPC) and distearoyl-SN-glycero-3-phosphoethanolamine-N-[methoxy(poly(ethylene glycol))-2000] (DSPE-PEG(2000), 5 mol %), formed by film hydration coupled with sequential extrusion. The nonentrapped particles were removed by flash gel exclusion chromatography. The magnetic-fluid-loaded liposomes (MFLs) were homogeneous in size (195 +/- 33 hydrodynamic diameters from quasi-elastic light scattering). Iron loading was varied from 35 up to 167 Fe(III)/lipid mol %. Physical and superparamagnetic characteristics of the iron oxide particles were preserved after liposome encapsulation as shown by cryogenic transmission electron microscopy and magnetization curve recording. In biological media, MFLs were highly stable and avoided ferrofluid flocculation while being nontoxic toward the J774 macrophage cell line. Moreover, steric stabilization ensured by PEG-surface-grafting significantly reduced liposome association with the macrophages. The ratios of the transversal (r2) and longitudinal (r1) magnetic resonance (MR) relaxivities of water protons in MFL dispersions (6 < r2/r1 < 18) ranked them among the best T2 contrast agents, the higher iron loading the better the T2 contrast enhancement. Magnetophoresis demonstrated the possible guidance of MFLs by applying a magnetic field gradient. Mouse MR imaging assessed MFLs efficiency as contrast agents in vivo: MR angiography performed 24 h after intravenous injection of the contrast agent provided the first direct evidence of the stealthiness of PEG-ylated magnetic-fluid-loaded liposomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Papahadjopoulos, D., Allen, T. M., Gabizon, A., Mayhew, E., Matthay, K., Huang, S. K., Lee, K. D., Woodle, M. C., Lasic, D. D., & Redemann, C. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11460 · Cited by 1,620
Comparative Properties and Methods of Preparation of Lipid Vesicles (Liposomes)
Szoka, F., & Papahadjopoulos, D. (1980) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.09.060180.002343 · Cited by 1,515
Allen, T. M., Hansen, C., Martin, F., Redemann, C., & Yau-Young, A. (1991) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(91)90246-5 · Cited by 1,391
Torchilin, V. P. (2000) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(00)00166-4 · Cited by 680
Chouly, C., Pouliquen, D., Lucet, I., Jeune, J. J., & Jallet, P. (1996) · Journal of Microencapsulation · doi:10.3109/02652049609026013 · Cited by 467
Long-circulating iron oxides for MR imaging
Weissleder, R., Bogdanov, A., Neuwelt, E. A., & Papisov, M. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00033-4 · Cited by 398
Functional magnetic particles for medical application
Shinkai, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(02)80202-x · Cited by 343
Functional Magnetic Particles for Medical Application.
SHINKAI, M. (2002) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.94.606 · Cited by 331
Pharmacokinetics of long-circulating liposomes
Allen, T. M., Hansen, C. B., & de Menezes, D. E. L. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00029-7 · Cited by 305
Tissue-specific MR contrast agents
Weinmann, H.-J., Ebert, W., Misselwitz, B., & Schmitt-Willich, H. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00332-7 · Cited by 250
Controlling liposome blood clearance by surface-grafted polymers
Woodle, M. C. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00136-1 · Cited by 242
Magnetoliposomes: Formation and structural characterization
De Cuyper, M., & Joniau, M. (1988) · European Biophysics Journal · doi:10.1007/bf00256482 · Cited by 239
Billotey, C., Wilhelm, C., Devaud, M., Bacri, J. C., Bittoun, J., & Gazeau, F. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10418 · Cited by 234
Self-citationSterically stabilized liposome therapeutics
Woodle, M. C. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00028-6 · Cited by 228
Possibility of active targeting to tumor tissues with liposomes
Maruyama, K., Ishida, O., Takizawa, T., & Moribe, K. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(99)00042-3 · Cited by 211
Delivery of diagnostic agents for magnetic resonance imaging
Okuhata, Y. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00103-3 · Cited by 145
Biomedical applications of maghemite ferrofluid
Halbreich, A., Roger, J., Pons, J.-N., Geldwerth, D., Silva, M. F. D., Roudier, M., & Bacri, J.-C. (1998) · Biochimie · doi:10.1016/s0300-9084(00)80006-1 · Cited by 134
Therapeutic opportunities for targeted liposomal drug delivery
Allen, T. M., & Moase, E. H. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00402-4 · Cited by 126
Polymeric Contrast Agents for Medical Imaging
Torchilin, V. P. (2000) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201003378960 · Cited by 126
Gløgård, C., Stensrud, G., Hovland, R., Fossheim, S. L., & Klaveness, J. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00935-8 · Cited by 101
Polymer-Grafted Liposomes: Physical Basis for the “Stealth” Property
Needham, D., Hristova, K. A., McIntosh, T. J., Dewhirst, M. W., Wu, N., & Lasiç, D. D. (1992) · Journal of Liposome Research · doi:10.3109/08982109209010218 · Cited by 101
Trubetskoy, V. S., Cannillo, J. A., Milshtein, A., Wolf, G. L., & Torchilin, V. P. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00083-f · Cited by 98
Lesieur, S., Grabielle-Madelmont, C., Ménager, C., Cabuil, V., Dadhi, D., Pierrot, P., & Edwards, K. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021471j · Cited by 81
Self-citationViroonchatapan, E., Ueno, M., Sato, H., Adachi, I., Nagae, H., Tazawa, K., & Horikoshi, I. (1995) · Pharmaceutical Research · doi:10.1023/a:1016216011016 · Cited by 79
Investigation of the magnetic properties of iron oxide nanoparticles used as contrast agent for MRI
Pouliquen, D., Perroud, H., Calza, F., JALLET, P., & Jeune, J. J. L. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240108 · Cited by 75
Liposomes and biopolymers in drug and gene delivery
Lasiç, D. D., & Papahadjopoulos, D. (1996) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(96)80031-3 · Cited by 72
Lesieur, S., Grabielle-Madelmont, C., Paternostre, M., & Ollivon, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90545-5 · Cited by 67
Self-citationMacromolecular systems for chemotherapy and magnetic resonance imaging
Matthews, S. E., Pouton, C. W., & Threadgill, M. D. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00098-r · Cited by 67
Bogdanov, A. A., Jr., Martin, C., Weissleder, R., & Brady, T. J. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90350-6 · Cited by 66
Beugin, S., Edwards, K., Karlsson, G., Ollivon, M., & Lesieur, S. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)78026-9 · Cited by 63
Self-citationRelease of 5-fluorouracil from thermosensitive magnetoliposomes induced by an electromagnetic field
Viroonchatapan, E., Sato, H., Ueno, M., Adachi, I., Tazawa, K., & Horikoshi, I. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(96)01606-9 · Cited by 59
Tilcock, C. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00109-4 · Cited by 52
The year(s) of the contrast agent – micro-MRI in the new millennium
Pautler, R. G., & Fraser, S. E. (2003) · Current Opinion in Immunology · doi:10.1016/s0952-7915(03)00073-6 · Cited by 46
Viroonchatapan, E., Sato, H., Ueno, M., Adachi, I., Murata, J., Saiki, I., Tazawa, K., & Horikoshi, I. (1998) · Journal of drug targeting · doi:10.3109/10611869808997865 · Cited by 41
Surface-modified liposomes in gamma- and MR-imaging
Torchilin, V. P. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00472-3 · Cited by 36
Biotinylated Stealth® magnetoliposomes
Hodenius, M., Cuyper, M. D., Desender, L., Müller-Schulte, D., Steigel, A., & Lueken, H. (2002) · Chemistry and Physics of Lipids · doi:10.1016/s0009-3084(02)00105-6 · Cited by 36
Microwave induced likage of magnetoliposomes. Possible clinical implications
Babincová, M. (1993) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(93)80037-u · Cited by 28
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
(2007) · doi:10.1007/978-3-540-37885-3 · Cited by 476
Huang, J., Li, Y., Orza, A., Lu, Q., Guo, P., Wang, L., Yang, L., & Mao, H. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504185 · Cited by 292
Cui, H., Hodgdon, T. K., Kaler, E. W., Abezgauz, L., Danino, D., Lubovsky, M., Talmon, Y., & Pochan, D. J. (2007) · Soft Matter · doi:10.1039/b704194b · Cited by 208
Metadata
- Authors
- Martina, M.-S., Fortin, J.-P., Ménager, C., Clément, O., Barratt, G., Grabielle-Madelmont, C., Gazeau, F., Cabuil, V., & Lesieur, S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-08
- Volume
- 127
- Issue
- 30
- Pages
- 10676-10685
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2037458039
- Cited by
- 441
- References
- 38
- FWCI
- 16.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.