The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A Reagentless Signal-On Architecture for Electronic, Aptamer-Based Sensors via Target-Induced Strand Displacement
Abstract
Thrombin binding stabilizes the alternative G-quadruplex conformation of the aptamer, liberating the methylene blue (MB)-tagged oligonucleotide to produce a flexible, single-stranded DNA element. This allows the MB tag to collide with the gold electrode surface, producing a readily detectable Faradaic current at thrombin concentrations as low as approximately 3 nM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Aptamer-Functionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin
Pavlov, V., Xiao, Y., Shlyahovsky, B., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046970u · Cited by 692
Self-citationMicromechanical Detection of Proteins Using Aptamer-Based Receptor Molecules
Savran, C. A., Knudsen, S. M., Ellington, A. D., & Manalis, S. R. (2004) · Analytical Chemistry · doi:10.1021/ac049859f · Cited by 310
A DNA‐Based Machine That Can Cyclically Bind and Release Thrombin
Dittmer, W. U., Reuter, A., & Simmel, F. C. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353537 · Cited by 254
Proximity extension of circular DNA aptamers with real-time protein detection
Di Giusto, D. A. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni063 · Cited by 192
The Vela glitch of Christmas 1988
McCulloch, P. M., Hamilton, P. A., McConnell, D., & King, E. A. (1990) · Nature · doi:10.1038/346822a0 · Cited by 184
Cited by
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection
Chang, H., Tang, L., Wang, Y., Jiang, J., & Li, J. (2010) · Analytical Chemistry · doi:10.1021/ac9025384 · Cited by 892
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Metadata
- Authors
- Xiao, Y., Piorek, B. D., Plaxco, K. W., & Heeger, A. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-12-01
- Volume
- 127
- Issue
- 51
- Pages
- 17990-17991
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2035620909
- Cited by
- 527
- References
- 7
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.