The DOI matches its Crossref record.
Antibiofouling Polymer-Coated Superparamagnetic Iron Oxide Nanoparticles as Potential Magnetic Resonance Contrast Agents for in Vivo Cancer Imaging
Abstract
We report the fabrication and characterization of antifouling polymer-coated magnetic nanoparticles as nanoprobes for magnetic resonance (MR) contrast agents. Magnetite superparamagnetic iron oxide nanoparticles (SPION) were coated with the protein- or cell-resistant polymer, poly(TMSMA-r-PEGMA), to generate stable, protein-resistant MR probes. Coated magnetic nanoparticles synthesized using two different preparation methods (in situ and stepwise, respectively) were both well dispersed in PBS buffer at a variety of pH conditions (pH 1-10). In addition, dynamic light scattering data revealed that their sizes were not altered even after 24 h of incubation in 10% serum containing cell culture medium, indicative of a lack of protein adsorption on their surfaces. When the antibiofouling polymer-coated SPION were incubated with macrophage cells, uptake was significantly lower in comparison to that of the popular contrast agent, Feridex I.V., suggesting that the polymer-coated SPION can be long-circulated in plasma by escaping from uptake by the reticular endothelial system (RES) such as macrophages. Indeed, when the coated SPION were administered to tumor xenograft mice by intravenous injection, the tumor could be detected in T2-weighted MR images within 1 h as a result of the accumulation of the nanomagnets within the tumor site. Although the poly(TMSMA-r-PEGMA)-coated SPION do not have any targeting ligands on their surface, they are potentially useful for cancer diagnosis in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Controlled drug delivery vehicles for cancer treatment and their performance
Senapati, S., Mahanta, A. K., Kumar, S., & Maiti, P. (2018) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-017-0004-3 · Cited by 2,167
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Lutz, J. (2008) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.22706 · Cited by 1,245
Oxidase‐Like Activity of Polymer‐Coated Cerium Oxide Nanoparticles
Asati, A., Santra, S., Kaittanis, C., Nath, S., & Perez, J. M. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805279 · Cited by 1,161
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Metadata
- Authors
- Lee, H., Lee, E., Kim, D. K., Jang, N. K., Jeong, Y. Y., & Jon, S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-06
- Volume
- 128
- Issue
- 22
- Pages
- 7383-7389
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2050955429
- Cited by
- 594
- References
- 0
- FWCI
- 27.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibiofouling Polymer-Coated Superparamagnetic Iron Oxide Nanoparticles as Potential Magnetic Resonance Contrast Agents for in Vivo Cancer Imaging. https://app.cochat.ai/papers/10.1021/ja061529k
- The paper
- Lee, H., Lee, E., Kim, D. K., Jang, N. K., Jeong, Y. Y., & Jon, S. (2006). Antibiofouling Polymer-Coated Superparamagnetic Iron Oxide Nanoparticles as Potential Magnetic Resonance Contrast Agents for in Vivo Cancer Imaging. Journal of the American Chemical Society. https://doi.org/10.1021/ja061529k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.