The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Detection of MicroRNAs Using Target-Guided Formation of Conducting Polymer Nanowires in Nanogaps
Abstract
A nanogapped microelectrode-based biosensor array is fabricated for ultrasensitive electrical detection of microRNAs (miRNAs). After peptide nucleic acid (PNA) capture probes were immobilized in nanogaps of a pair of interdigitated microelectrodes and hybridization was performed with their complementary target miRNA, the deposition of conducting polymer nanowires, polyaniline (PAn) nanowires, is carried out by an enzymatically catalyzed method, where the electrostatic interaction between anionic phosphate groups in miRNA and cationic aniline molecules is exploited to guide the formation of the PAn nanowires onto the hybridized target miRNA. The conductance of the deposited PAn nanowires correlates directly to the amount of the hybridized miRNA. Under optimized conditions, the target miRNA can be quantified in a range from 10 fM to 20 pM with a detection limit of 5.0 fM. The biosensor array is applied to the direct detection of miRNA in total RNA extracted from cancer cell lines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A microRNA array reveals extensive regulation of microRNAs during brain development
KRICHEVSKY, A. M., KING, K. S., DONAHUE, C. P., KHRAPKO, K., & KOSIK, K. S. (2003) · RNA · doi:10.1261/rna.5980303 · Cited by 1,040
Fluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Barad, O., Meiri, E., Avniel, A., Aharonov, R., Barzilai, A., Bentwich, I., Einav, U., Gilad, S., Hurban, P., Karov, Y., et al. (2004) · Genome Research · doi:10.1101/gr.2845604 · Cited by 582
Probing microRNAs with microarrays: tissue specificity and functional inference
BABAK, T., ZHANG, W., MORRIS, Q., BLENCOWE, B. J., & HUGHES, T. R. (2004) · RNA · doi:10.1261/rna.7119904 · Cited by 385
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationMicroRNA: Function, Detection, and Bioanalysis
Dong, H., Lei, J., Ding, L., Wen, Y., Ju, H., & Zhang, X. (2013) · Chemical Reviews · doi:10.1021/cr300362f · Cited by 1,224
Ultrasensitive detection of miRNA with an antimonene-based surface plasmon resonance sensor
Xue, T., Liang, W., Li, Y., Sun, Y., Xiang, Y., Zhang, Y., Dai, Z., Duo, Y., Wu, L., Qi, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07947-8 · Cited by 764
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Conducting Polyaniline Nanowire and Its Applications in Chemiresistive Sensing
Song, E., & Choi, J.-W. (2013) · Nanomaterials · doi:10.3390/nano3030498 · Cited by 462
Metadata
- Authors
- Fan, Y., Chen, X., Trigg, A. D., Tung, C.-H., Kong, J., & Gao, Z.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-04-06
- Volume
- 129
- Issue
- 17
- Pages
- 5437-5443
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2093385199
- Cited by
- 219
- References
- 4
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of MicroRNAs Using Target-Guided Formation of Conducting Polymer Nanowires in Nanogaps. https://app.cochat.ai/papers/10.1021/ja067477g
- The paper
- Fan, Y., Chen, X., Trigg, A. D., Tung, C.-H., Kong, J., & Gao, Z. (2007). Detection of MicroRNAs Using Target-Guided Formation of Conducting Polymer Nanowires in Nanogaps. Journal of the American Chemical Society. https://doi.org/10.1021/ja067477g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.