The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Spotlighting of Cocaine by an Autonomous Aptamer-Based Machine
Abstract
An aptamer-based machine is used for the amplified detection of the low-molecular-weight analyte, cocaine. The aptamer sequence recognizing cocaine, 1, is blocked to an inactive structure through its hybridization with 1a . In the presence of cocaine, 2, the blocked aptamer is folded to form the cocaine-aptamer complex 3, while releasing 1a . In the presence of the nucleotide mixture, dNTPs, polymerase, and the nicking enzyme Nt.BbvC I, a polymerization-nicking and strand displacement is initiated on the cocaine−aptamer complex that acts as “track”. The displaced strand 4 hybridizes with a hairpin nucleic structure 5 that is functionalized at the two ends of the “stem” by a dye (FAM)/quencher (TAMRA) couple. The fluorescence of the dye is quenched by TAMRA in the “hairpin” structure. The opening of the “hairpin” structure through hybridization with 4 restores the fluorescence of the dye (λ ex = 480 nm; λ em = 520 nm). The resulting fluorescence signal provides a readout signal for the operation of the aptamer-based machine and for the detection of cocaine. The system enabled the analysis of cocaine with a detection limit that corresponded to 5 × 10 -6 M.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Aptamer-Functionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin
Pavlov, V., Xiao, Y., Shlyahovsky, B., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046970u · Cited by 692
Self-citationPolsky, R., Gill, R., Kaganovsky, L., & Willner, I. (2006) · Analytical Chemistry · doi:10.1021/ac0519864 · Cited by 459
Self-citationBeissenhirtz, M. K., & Willner, I. (2006) · Organic & Biomolecular Chemistry · doi:10.1039/b607033g · Cited by 201
Self-citation
Cited by
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Principles and Applications of Nucleic Acid Strand Displacement Reactions
Simmel, F. C., Yurke, B., & Singh, H. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00580 · Cited by 792
DNAzymes for sensing, nanobiotechnology and logic gate applications
Willner, I., Shlyahovsky, B., Zayats, M., & Willner, B. (2008) · Chemical Society Reviews · doi:10.1039/b718428j · Cited by 791
Self-citationOptical Analysis of Hg2+ Ions by Oligonucleotide–Gold‐Nanoparticle Hybrids and DNA‐Based Machines
Li, D., Wieckowska, A., & Willner, I. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200705991 · Cited by 682
Self-citationWang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Self-citationNucleic Acid Based Molecular Devices
Krishnan, Y., & Simmel, F. C. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.200907223 · Cited by 572
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Jimmy Huang, P.-J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Visual Cocaine Detection with Gold Nanoparticles and Rationally Engineered Aptamer Structures
Zhang, J., Wang, L., Pan, D., Song, S., Boey, F. Y. C., Zhang, H., & Fan, C. (2008) · Small · doi:10.1002/smll.200800057 · Cited by 408
Functionalized DNA Nanostructures
Wilner, O. I., & Willner, I. (2012) · Chemical Reviews · doi:10.1021/cr200104q · Cited by 399
Self-citationRationally designed molecular beacons for bioanalytical and biomedical applications
Zheng, J., Yang, R., Shi, M., Wu, C., Fang, X., Li, Y., Li, J., & Tan, W. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00020c · Cited by 372
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C., Liu, H., Zou, Y., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905570 · Cited by 364
Optical aptasensors for quantitative detection of small biomolecules: A review
Feng, C., Dai, S., & Wang, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.014 · Cited by 300
Wen, Y., Pei, H., Wan, Y., Su, Y., Huang, Q., Song, S., & Fan, C. (2011) · Analytical Chemistry · doi:10.1021/ac201491p · Cited by 265
Metadata
- Authors
- Shlyahovsky, B., Li, D., Weizmann, Y., Nowarski, R., Kotler, M., & Willner, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-03-13
- Volume
- 129
- Issue
- 13
- Pages
- 3814-3815
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1987793310
- Cited by
- 272
- References
- 4
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.