The DOI matches its Crossref record.
Design, Synthesis, and Imaging of an Activatable Photoacoustic Probe
Open accessAbstract
Photoacoustic tomography is a rapidly growing imaging modality that can provide images of high spatial resolution and high contrast at depths up to 5 cm. We report here the design, synthesis, and evaluation of an activatable probe that shows great promise for enabling detection of the cleaved probe in the presence of high levels of nonactivated, uncleaved probe, a difficult task to attain in absorbance-based modality. Before the cleavage by its target, proteolytic enzyme MMP-2, the probe, an activatable cell-penetrating peptide, Ceeee[Ahx]PLGLAGrrrrrK, labeled with two chromophores, BHQ3 and Alexa750, shows photoacoustic signals of similar intensity at the two wavelengths corresponding to the absorption maxima of the chromophores, 675 and 750 nm. Subtraction of the images taken at these two wavelengths makes the probe effectively photoacoustically silent, as the signals at these two wavelengths essentially cancel out. After the cleavage, the dye associated with the cell-penetrating part of the probe, BHQ3, accumulates in the cells, while the other dye diffuses away, resulting in photoacoustic signal seen at only one of the wavelengths, 675 nm. Subtraction of the photoacoustic images at two wavelengths reveals the location of the cleaved (activated) probe. In the search for the chromophores that are best suited for photoacoustic imaging, we have investigated the photoacoustic signals of five chromophores absorbing in the near-infrared region. We have found that the photoacoustic signal did not correlate with the absorbance and fluorescence of the molecules, as the highest photoacoustic signal arose from the least absorbing quenchers, BHQ3 and QXL 680.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Self‐Assembled Peptide‐Based Nanomaterials for Biomedical Imaging and Therapy
Qi, G., Gao, Y., Wang, L., & Wang, H. (2018) · Advanced Materials · doi:10.1002/adma.201703444 · Cited by 527
Lyu, Y., Zeng, J., Jiang, Y., Zhen, X., Wang, T., Qiu, S., Lou, X., Gao, M., & Pu, K. (2018) · ACS Nano · doi:10.1021/acsnano.7b08616 · Cited by 357
Qi, J., Chen, C., Zhang, X., Hu, X., Ji, S., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2018) · Nature Communications · doi:10.1038/s41467-018-04222-8 · Cited by 350
Diketopyrrolopyrrole‐Based Semiconducting Polymer Nanoparticles for In Vivo Photoacoustic Imaging
Pu, K., Mei, J., Jokerst, J. V., Hong, G., Antaris, A. L., Chattopadhyay, N., Shuhendler, A. J., Kurosawa, T., Zhou, Y., Gambhir, S. S., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502285 · Cited by 332
Self-citation
Metadata
- Authors
- Levi, J., Kothapalli, S. R., Ma, T.-J., Hartman, K., Khuri-Yakub, B. T., & Gambhir, S. S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-22
- Volume
- 132
- Issue
- 32
- Pages
- 11264-11269
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1967452415
- Cited by
- 177
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design, Synthesis, and Imaging of an Activatable Photoacoustic Probe. https://app.cochat.ai/papers/10.1021/ja104000a
- The paper
- Levi, J., Kothapalli, S. R., Ma, T.-J., Hartman, K., Khuri-Yakub, B. T., & Gambhir, S. S. (2010). Design, Synthesis, and Imaging of an Activatable Photoacoustic Probe. Journal of the American Chemical Society. https://doi.org/10.1021/ja104000a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.