Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Gas Sensing with High-Resolution Localized Surface Plasmon Resonance Spectroscopy

Open access
Bingham, Julia M., Anker, Jeffrey N., Kreno, Lauren E., Van Duyne, Richard P.·2010·Journal of the American Chemical Society

Abstract

We report the first inert gas sensing and characterization studies based on high-resolution localized surface plasmon resonance (HR-LSPR) spectroscopy. HR-LSPR was used to detect the extremely small changes (<3 × 10(-4)) in bulk refractive index when the gas was switched between He(g) and Ar(g) or He(g) and N2(g). We also demonstrate submonolayer sensitivity to adsorbed water from exposure of the sensor to air (40% humidity) versus dry N2(g). These measurements significantly expand the applications space and characterization tools for plasmonic nanosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja1074272

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Bingham, J. M., Anker, J. N., Kreno, L. E., & Van Duyne, R. P.
Venue
Journal of the American Chemical Society
Published
2010-11-22
Volume
132
Issue
49
Pages
17358-17359
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2020843943
Cited by
232
References
2
FWCI
8.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gas Sensing with High-Resolution Localized Surface Plasmon Resonance Spectroscopy. https://app.cochat.ai/papers/10.1021/ja1074272
The paper
Bingham, J. M., Anker, J. N., Kreno, L. E., & Van Duyne, R. P. (2010). Gas Sensing with High-Resolution Localized Surface Plasmon Resonance Spectroscopy. Journal of the American Chemical Society. https://doi.org/10.1021/ja1074272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.