The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Stepwise Synthesis of Giant Unilamellar Vesicles on a Microfluidic Assembly Line
Open accessAbstract
Among the molecular milieu of the cell, the membrane bilayer stands out as a complex and elusive synthetic target. We report a microfluidic assembly line that produces uniform cellular compartments from droplet, lipid, and oil/water interface starting materials. Droplets form in a lipid-containing oil flow and travel to a junction where the confluence of oil and extracellular aqueous media establishes a flow-patterned interface that is both stable and reproducible. A triangular post mediates phase transfer bilayer assembly by deflecting droplets from oil, through the interface, and into the extracellular aqueous phase to yield a continuous stream of unilamellar phospholipid vesicles with uniform and tunable size. The size of the droplet precursor dictates vesicle size, encapsulation of small-molecule cargo is highly efficient, and the single bilayer promotes functional insertion of a bacterial transmembrane pore.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion of univalent ions across the lamellae of swollen phospholipids
Bangham, A. D., Standish, M. M., & Watkins, J. C. (1965) · Journal of Molecular Biology · doi:10.1016/s0022-2836(65)80093-6 · Cited by 4,664
A vesicle bioreactor as a step toward an artificial cell assembly
Noireaux, V., & Libchaber, A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408236101 · Cited by 1,152
Template-directed synthesis of a genetic polymer in a model protocell
Mansy, S. S., Schrum, J. P., Krishnamurthy, M., Tobé, S., Treco, D. A., & Szostak, J. W. (2008) · Nature · doi:10.1038/nature07018 · Cited by 684
Cited by
A Comprehensive Survey of Recent Advancements in Molecular Communication
Farsad, N., Yilmaz, H. B., Eckford, A., Chae, C.-B., & Guo, W. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2527741 · Cited by 968
Microfluidic methods for forming liposomes
van Swaay, D., & deMello, A. (2013) · Lab on a Chip · doi:10.1039/c2lc41121k · Cited by 379
Octanol-assisted liposome assembly on chip
Deshpande, S., Caspi, Y., Meijering, A. E. C., & Dekker, C. (2016) · Nature Communications · doi:10.1038/ncomms10447 · Cited by 363
A comprehensive review on recent preparation techniques of liposomes
Has, C., & Sunthar, P. (2020) · Journal of Liposome Research · doi:10.1080/08982104.2019.1668010 · Cited by 357
Maeki, M., Kimura, N., Sato, Y., Harashima, H., & Tokeshi, M. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.008 · Cited by 319
Metadata
- Authors
- Matosevic, S., & Paegel, B. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-10
- Volume
- 133
- Issue
- 9
- Pages
- 2798-2800
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1976493992
- Cited by
- 205
- References
- 3
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.