The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Deep-UV Surface-Enhanced Resonance Raman Scattering of Adenine on Aluminum Nanoparticle Arrays
Abstract
We report the ultrasensitive detection of adenine using deep-UV surface-enhanced resonance Raman scattering on aluminum nanostructures. Well-defined Al nanoparticle arrays fabricated over large areas using extreme-UV interference lithography exhibited sharp and tunable plasmon resonances in the UV and deep-UV wavelength ranges. Theoretical modeling based on the finite-difference time-domain method was used to understand the near-field and far-field optical properties of the nanoparticle arrays. Raman measurements were performed on adenine molecules coated uniformly on the Al nanoparticle arrays at a laser excitation wavelength of 257.2 nm. With this technique, less than 10 amol of label-free adenine molecules could be detected reproducibly in real time. Zeptomole (~30,000 molecules) detection sensitivity was readily achieved proving that deep-UV surface-enhanced resonance Raman scattering is an extremely sensitive tool for the detection of biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA Excited-State Dynamics: From Single Bases to the Double Helix
Middleton, C. T., de La Harpe, K., Su, C., Law, Y. K., Crespo-Hernández, C. E., & Kohler, B. (2009) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093719 · Cited by 827
Deep-UV surface-enhanced Raman scattering
Dörfer, T., Schmitt, M., & Popp, J. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1831 · Cited by 141
Cited by
Knight, M. W., King, N. S., Liu, L., Everitt, H. O., Nordlander, P., & Halas, N. J. (2014) · ACS Nano · doi:10.1021/nn405495q · Cited by 1,261
Plasmonic Films Can Easily Be Better: Rules and Recipes
McPeak, K. M., Jayanti, S. V., Kress, S. J. P., Meyer, S., Iotti, S., Rossinelli, A., & Norris, D. J. (2015) · ACS Photonics · doi:10.1021/ph5004237 · Cited by 1,047
Plasmonic films can easily be better: Rules and recipes
McPeak, K. M., Jayanti, S. V., Kress, S. J. P., Meyer, S., Iotti, S., Rossinelli, A. A., & Norris, D. J. (2015) · doi:10.3929/ethz-b-000100036 · Cited by 616
Plasmonics in the ultraviolet with the poor metals Al, Ga, In, Sn, Tl, Pb, and Bi
McMahon, J. M., Schatz, G. C., & Gray, S. K. (2013) · Phys. Chem. Chem. Phys. · doi:10.1039/c3cp43856b · Cited by 371
Infrared Plasmonic Biosensor for Real-Time and Label-Free Monitoring of Lipid Membranes
Limaj, O., Etezadi, D., Wittenberg, N. J., Rodrigo, D., Yoo, D., Oh, S.-H., & Altug, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b05316 · Cited by 196
Metadata
- Authors
- Jha, S. K., Ahmed, Z., Agio, M., Ekinci, Y., & Löffler, J. F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-19
- Volume
- 134
- Issue
- 4
- Pages
- 1966-1969
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1985470401
- Cited by
- 258
- References
- 2
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep-UV Surface-Enhanced Resonance Raman Scattering of Adenine on Aluminum Nanoparticle Arrays. https://app.cochat.ai/papers/10.1021/ja210446w
- The paper
- Jha, S. K., Ahmed, Z., Agio, M., Ekinci, Y., & Löffler, J. F. (2012). Deep-UV Surface-Enhanced Resonance Raman Scattering of Adenine on Aluminum Nanoparticle Arrays. Journal of the American Chemical Society. https://doi.org/10.1021/ja210446w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.