The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Protein Detection by Nanopores Equipped with Aptamers
Open accessAbstract
Protein nanopores have been used as stochastic sensors for the detection of analytes that range from small molecules to proteins. In this approach, individual analyte molecules modulate the ionic current flowing through a single nanopore. Here, a new type of stochastic sensor based on an αHL pore modified with an aptamer is described. The aptamer is bound to the pore by hybridization to an oligonucleotide that is attached covalently through a disulfide bond to a single cysteine residue near a mouth of the pore. We show that the binding of thrombin to a 15-mer DNA aptamer, which forms a cation-stabilized quadruplex, alters the ionic current through the pore. The approach allows the quantification of nanomolar concentrations of thrombin, and provides association and dissociation rate constants and equilibrium dissociation constants for thrombin·aptamer interactions. Aptamer-based nanopores have the potential to be integrated into arrays for the parallel detection of multiple analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Selection of single-stranded DNA molecules that bind and inhibit human thrombin
Bock, L. C., Griffin, L. C., Latham, J. A., Vermaas, E. H., & Toole, J. J. (1992) · Nature · doi:10.1038/355564a0 · Cited by 2,469
Dekker, C. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.27 · Cited by 1,933
In Vitro Selection of Functional Nucleic Acids
Wilson, D. S., & Szostak, J. W. (1999) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.68.1.611 · Cited by 1,206
Nanopore analytics: sensing of single molecules
Howorka, S., & Siwy, Z. (2009) · Chemical Society Reviews · doi:10.1039/b813796j · Cited by 1,170
Stochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
Self-citationAnalytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Aptamers: An Emerging Class of Therapeutics
Nimjee, S. M., Rusconi, C. P., & Sullenger, B. A. (2005) · Annual Review of Medicine · doi:10.1146/annurev.med.56.062904.144915 · Cited by 937
Thrombin-binding DNA aptamer forms a unimolecular quadruplex structure in solution.
Macaya, R. F., Schultze, P., Smith, F. W., Roe, J. A., & Feigon, J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3745 · Cited by 887
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Sequence-specific detection of individual DNA strands using engineered nanopores
Howorka, S., Cheley, S., & Bayley, H. (2001) · Nature Biotechnology · doi:10.1038/90236 · Cited by 760
Self-citationKinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Resistive-Pulse SensingFrom Microbes to Molecules
Bayley, H., & Martin, C. R. (2000) · Chemical Reviews · doi:10.1021/cr980099g · Cited by 526
Self-citationEngineered voltage-responsive nanopores
Siwy, Z. S., & Howorka, S. (2010) · Chem. Soc. Rev. · doi:10.1039/b909105j · Cited by 500
The structure of alpha-thrombin inhibited by a 15-mer single-stranded DNA aptamer.
Padmanabhan, K., Padmanabhan, K. P., Ferrara, J. D., Sadler, J. E., & Tulinsky, A. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)46749-4 · Cited by 468
THE STRUCTURE OF ALPHA-THROMBIN INHIBITED BY A 15-MER SINGLE-STRANDED DNA APTAMER: 1hut
Padmanabhan, K., Padmanabhan, K. P., Ferrara, J. D., Sadler, J. E., & Tulinsky, A. (1994) · Worldwide Protein Data Bank · doi:10.2210/pdb1hut/pdb · Cited by 426
Movileanu, L., Howorka, S., Braha, O., & Bayley, H. (2000) · Nature Biotechnology · doi:10.1038/80295 · Cited by 366
Self-citationA DNA aptamer which binds to and inhibits thrombin exhibits a new structural motif for DNA
Wang, K. Y., McCurdy, S., Shea, R. G., Swaminathan, S., & Bolton, P. H. (1993) · Biochemistry · doi:10.1021/bi00059a003 · Cited by 332
Applications of biological pores in nanomedicine, sensing, and nanoelectronics
Majd, S., Yusko, E. C., Billeh, Y. N., Macrae, M. X., Yang, J., & Mayer, M. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.05.002 · Cited by 327
[13] Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Morton, T. A., & Myszka, D. G. (1998) · Methods in Enzymology · doi:10.1016/s0076-6879(98)95044-3 · Cited by 308
Hybrid pore formation by directed insertion of α-haemolysin into solid-state nanopores
Hall, A. R., Scott, A., Rotem, D., Mehta, K. K., Bayley, H., & Dekker, C. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.237 · Cited by 308
Self-citationShamah, S. M., Healy, J. M., & Cload, S. T. (2008) · Accounts of Chemical Research · doi:10.1021/ar700142z · Cited by 304
Designed protein pores as components for biosensors
Braha, O., Walker, B., Cheley, S., Kasianowicz, J. J., Song, L., Gouaux, J. E., & Bayley, H. (1997) · Chemistry & Biology · doi:10.1016/s1074-5521(97)90321-5 · Cited by 302
Self-citationKinetics of duplex formation for individual DNA strands within a single protein nanopore
Howorka, S., Movileanu, L., Braha, O., & Bayley, H. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.231434698 · Cited by 205
Self-citationBerezovski, M. V., Nutiu, R., Li, Y., & Krylov, S. N. (2003) · Analytical Chemistry · doi:10.1021/ac026214b · Cited by 145
Screening Blockers Against a Potassium Channel with a Droplet Interface Bilayer Array
Syeda, R., Holden, M. A., Hwang, W. L., & Bayley, H. (2008) · Journal of the American Chemical Society · doi:10.1021/ja804968g · Cited by 142
Self-citationSingle‐Molecule Kinetics of Two‐Step Divalent Cation Chelation
Hammerstein, A. F., Shin, S., & Bayley, H. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906601 · Cited by 49
Self-citation
Cited by
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Xue, L., Yamazaki, H., Ren, R., Wanunu, M., Ivanov, A. P., & Edel, J. B. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0229-6 · Cited by 647
Nanopore-based technologies beyond DNA sequencing
Ying, Y.-L., Hu, Z.-L., Zhang, S., Qing, Y., Fragasso, A., Maglia, G., Meller, A., Bayley, H., Dekker, C., & Long, Y.-T. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01193-2 · Cited by 538
Self-citationSolid-state and biological nanopore for real-time sensing of single chemical and sequencing of DNA
Haque, F., Li, J., Wu, H.-C., Liang, X.-J., & Guo, P. (2013) · Nano Today · doi:10.1016/j.nantod.2012.12.008 · Cited by 421
Targeting the N terminus for site-selective protein modification
Rosen, C. B., & Francis, M. B. (2017) · Nature Chemical Biology · doi:10.1038/nchembio.2416 · Cited by 389
Metadata
- Authors
- Rotem, D., Jayasinghe, L., Salichou, M., & Bayley, H.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-26
- Volume
- 134
- Issue
- 5
- Pages
- 2781-2787
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2062415820
- Cited by
- 312
- References
- 28
- FWCI
- 19.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.