Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Designed protein pores as components for biosensors

Open access
Braha, Orit, Walker, Barbara, Cheley, Stephen, Kasianowicz, John J., Song, Langzhou, Gouaux, J.Eric, Bayley, Hagan·1997·Chemistry & Biology

Abstract

BACKGROUND: There is a pressing need for new sensors that can detect a variety of analytes, ranging from simple ions to complex compounds and even microorganisms. The devices should offer sensitivity, speed, reversibility and selectivity. Given these criteria, protein pores, remodeled so that their transmembrane conductances are modulated by the association of specific analytes, are excellent prospects as components of biosensors. RESULTS: Structure-based design and a separation method that employs targeted chemical modification have been used to obtain a heteromeric form of the bacterial pore-forming protein staphylococcal alpha-hemolysin, in which one of the seven subunits contains a binding site for a divalent metal ion, M(II), which serves as a prototypic analyte. The single-channel current of the heteromer in planar bilayers is modulated by nanomolar Zn(II). Other M(II)s modulate the current and produce characteristic signatures. In addition, heteromers containing more than one mutant subunit exhibit distinct responses to M(II)s Hence, a large collection of responsive pores can be generated through subunit diversity and combinatorial assembly. CONCLUSIONS: Engineered pores have several advantages as potential sensor elements: sensitivity is in the nanomolar range; analyte binding is rapid (diffusion limited in some cases) and reversible; strictly selective binding is not required because single-channel recordings are rich in information; and for a particular analyte, the dissociation rate constant, the extent of channel block and the voltage-dependence of these parameters are distinguishing, while the frequency of partial channel block reflects the analyte concentration. A single sensor element might, therefore, be used to quantitate more than one analyte at once. The approach described here can be generalized for additional analytes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1074-5521(97)90321-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 302

Metadata

Authors
Braha, O., Walker, B., Cheley, S., Kasianowicz, J. J., Song, L., Gouaux, J. E., & Bayley, H.
Venue
Chemistry & Biology
Publisher
Elsevier BV
Published
1997-07
Volume
4
Issue
7
Pages
497-505
ISSN
1074-5521 (ISSN-L)
OpenAlex
W4244913051
Cited by
302
References
1
FWCI
10.03
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Designed protein pores as components for biosensors. https://app.cochat.ai/papers/10.1016/s1074-5521(97)90321-5
The paper
Braha, O., Walker, B., Cheley, S., Kasianowicz, J. J., Song, L., Gouaux, J. E., & Bayley, H. (1997). Designed protein pores as components for biosensors. Chemistry & Biology. https://doi.org/10.1016/s1074-5521(97)90321-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.