The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Reduced Graphene Oxide Conjugated Cu2O Nanowire Mesocrystals for High-Performance NO2 Gas Sensor
Abstract
Reduced graphene oxide (rGO)-conjugated Cu(2)O nanowire mesocrystals were formed by nonclassical crystallization in the presence of GO and o-anisidine under hydrothermal conditions. The resultant mesocrystals are comprised of highly anisotropic nanowires as building blocks and possess a distinct octahedral morphology with eight {111} equivalent crystal faces. The mechanisms underlying the sequential formation of the mesocrystals are as follows: first, GO-promoted agglomeration of amorphous spherical Cu(2)O nanoparticles at the initial stage, leading to the transition of growth mechanism from conventional ion-by-ion growth to particle-mediated crystallization; second, the evolution of the amorphous microspheres into hierarchical structure, and finally to nanowire mesocrystals through mesoscale transformation, where Ostwald ripening is responsible for the growth of the nanowire building blocks; third, large-scale self-organization of the mesocrystals and the reduction of GO (at high GO concentration) occur simultaneously, resulting in an integrated hybrid architecture where porous three-dimensional (3D) framework structures interspersed among two-dimensional (2D) rGO sheets. Interestingly, "super-mesocrystals" formed by 3D oriented attachment of mesocrystals are also formed judging from the voided Sierpinski polyhedrons observed. Furthermore, the interior nanowire architecture of these mesocrystals can be kinetically controlled by careful variation of growth conditions. Owing to high specific surface area and improved conductivity, the rGO-Cu(2)O mesocrystals achieved a higher sensitivity toward NO(2) at room temperature, surpassing the performance of standalone systems of Cu(2)O nanowires networks and rGO sheets. The unique characteristics of rGO-Cu(2)O mesocrystal point to its promising applications in ultrasensitive environmental sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of Graphitic Oxide
Hummers, W. S., & Offeman, R. E. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01539a017 · Cited by 29,920
Co3O4 nanocrystals on graphene as a synergistic catalyst for oxygen reduction reaction
Liang, Y., Li, Y., Wang, H., Zhou, J., Wang, J., Regier, T., & Dai, H. (2011) · Nature Materials · doi:10.1038/nmat3087 · Cited by 5,494
Nanomaterials: A Membrane-Based Synthetic Approach
Martin, C. R. (1994) · Science · doi:10.1126/science.266.5193.1961 · Cited by 4,060
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
New insights into the structure and reduction of graphite oxide
Gao, W., Alemany, L. B., Ci, L., & Ajayan, P. M. (2009) · Nature Chemistry · doi:10.1038/nchem.281 · Cited by 2,583
Higher‐Order Organization by Mesoscale Self‐Assembly and Transformation of Hybrid Nanostructures
Cölfen, H., & Mann, S. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200562 · Cited by 1,816
Graphene Oxide Sheets at Interfaces
Kim, J., Cote, L. J., Kim, F., Yuan, W., Shull, K. R., & Huang, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102777p · Cited by 1,762
Xu, S., Qin, Y., Xu, C., Wei, Y., Yang, R., & Wang, Z. L. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.46 · Cited by 1,626
Practical Chemical Sensors from Chemically Derived Graphene
Fowler, J. D., Allen, M. J., Tung, V. C., Yang, Y., Kaner, R. B., & Weiller, B. H. (2009) · ACS Nano · doi:10.1021/nn800593m · Cited by 1,447
Molecular tectonics in biomineralization and biomimetic materials chemistry
Mann, S. (1993) · Nature · doi:10.1038/365499a0 · Cited by 1,165
Cited by
Yuan, W., & Shi, G. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta11774j · Cited by 1,073
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Yin, P. T., Shah, S., Chhowalla, M., & Lee, K.-B. (2015) · Chemical Reviews · doi:10.1021/cr500537t · Cited by 718
25th Anniversary Article: Hybrid Nanostructures Based on Two‐Dimensional Nanomaterials
Huang, X., Tan, C., Yin, Z., & Zhang, H. (2014) · Advanced Materials · doi:10.1002/adma.201304964 · Cited by 632
A Review on Graphene-Based Gas/Vapor Sensors with Unique Properties and Potential Applications
Wang, T., Huang, D., Yang, Z., Xu, S., He, G., Li, X., Hu, N., Yin, G., He, D., & Zhang, L. (2016) · Nano-Micro Letters · doi:10.1007/s40820-015-0073-1 · Cited by 600
Song, Z., Wei, Z., Wang, B., Luo, Z., Xu, S., Zhang, W., Yu, H., Li, M., Huang, Z., Zang, J., et al. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04850 · Cited by 438
Gas Sensors Based on Chemi-Resistive Hybrid Functional Nanomaterials
Jian, Y., Hu, W., Zhao, Z., Cheng, P., Haick, H., Yao, M., & Wu, W. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0407-5 · Cited by 429
Cui, S., Wen, Z., Huang, X., Chang, J., & Chen, J. (2015) · Small · doi:10.1002/smll.201402923 · Cited by 406
Recent advances in carbon material-based NO2 gas sensors
Lee, S. W., Lee, W., Hong, Y., Lee, G., & Yoon, D. S. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.08.203 · Cited by 304
A room-temperature NO2 gas sensor based on CuO nanoflakes modified with rGO nanosheets
Bai, H., Guo, H., Wang, J., Dong, Y., Liu, B., Xie, Z., Guo, F., Chen, D., Zhang, R., & Zheng, Y. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129783 · Cited by 293
Sun, S., Zhang, X., Yang, Q., Liang, S., Zhang, X., & Yang, Z. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2018.03.006 · Cited by 283
Recent Advances in Emerging 2D Material‐Based Gas Sensors: Potential in Disease Diagnosis
Zhang, L., Khan, K., Zou, J., Zhang, H., & Li, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901329 · Cited by 281
Wu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225
Jiang, D., Xue, J., Wu, L., Zhou, W., Zhang, Y., & Li, X. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.04.034 · Cited by 183
Three-Dimensional Crumpled Graphene-Based Nanosheets with Ultrahigh NO 2 Gas Sensibility
Chen, Z., Wang, J., Umar, A., Wang, Y., Li, H., & Zhou, G. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b01229 · Cited by 120
Metadata
- Authors
- Deng, S., Tjoa, V., Fan, H. M., Tan, H. R., Sayle, D. C., Olivo, M., Mhaisalkar, S., Wei, J., & Sow, C. H.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-27
- Volume
- 134
- Issue
- 10
- Pages
- 4905-4917
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2164878199
- Cited by
- 757
- References
- 50
- FWCI
- 32.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.