The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Orange Fluorescent Protein with a Large Stokes Shift for Single-Excitation Multicolor FCCS and FRET Imaging
Open accessAbstract
Multicolor imaging based on genetically encoded fluorescent proteins (FPs) is a powerful approach to study several dynamic processes in a live cell. We report a monomeric orange FP with a large Stokes shift (LSS), called LSSmOrange (excitation/emission at 437/572 nm), which fills up an existing spectral gap between the green-yellow and red LSSFPs. Brightness of LSSmOrange is five-fold larger than that of the brightest red LSSFP and similar to the green-yellow LSSFPs. LSSmOrange allows numerous multicolor applications using a single-excitation wavelength that was not possible before. Using LSSmOrange we developed four-color single-laser fluorescence cross-correlation spectroscopy, solely based on FPs. The quadruple cross-correlation combined with photon counting histogram techniques allowed quantitative single-molecule analysis of particles labeled with four FPs. LSSmOrange was further applied to simultaneously image two Förster resonance energy transfer pairs, one of which is the commonly used CFP-YFP pair, with a single-excitation laser line. The combination of LSSmOrange-mKate2 and CFP-YFP biosensors enabled imaging of apoptotic activity and calcium fluctuations in real time. The LSSmOrange mutagenesis, low-temperature, and isotope effect studies revealed a proton relay for the excited-state proton transfer responsible for the LSS phenotype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Cited by
Advances in fluorescence labeling strategies for dynamic cellular imaging
Dean, K. M., & Palmer, A. E. (2014) · Nature Chemical Biology · doi:10.1038/nchembio.1556 · Cited by 512
DNA Nanoflowers for Multiplexed Cellular Imaging and Traceable Targeted Drug Delivery
Hu, R., Zhang, X., Zhao, Z., Zhu, G., Chen, T., Fu, T., & Tan, W. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400323 · Cited by 337
Chu, J., Oh, Y., Sens, A., Ataie, N., Dana, H., Macklin, J. J., Laviv, T., Welf, E. S., Dean, K. M., Zhang, F., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3550 · Cited by 293
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Li, T., Yang, D., Zhai, L., Wang, S., Zhao, B., Fu, N., Wang, L., Tao, Y., & Huang, W. (2017) · Advanced Science · doi:10.1002/advs.201600166 · Cited by 138
Selective filtering of excitatory inputs to nucleus accumbens by dopamine and serotonin
Christoffel, D. J., Walsh, J. J., Hoerbelt, P., Heifets, B. D., Llorach, P., Lopez, R. C., Ramakrishnan, C., Deisseroth, K., & Malenka, R. C. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2106648118 · Cited by 54
Metadata
- Authors
- Shcherbakova, D. M., Hink, M. A., Joosen, L., Gadella, T. W. J., & Verkhusha, V. V.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-24
- Volume
- 134
- Issue
- 18
- Pages
- 7913-7923
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2129730078
- Cited by
- 249
- References
- 1
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.