The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Smart Near-Infrared Fluorescence Probes with Donor–Acceptor Structure for in Vivo Detection of β-Amyloid Deposits
Abstract
The deposition of β-amyloid (Aβ) plaques in the parenchymal and cortical brain is accepted as the main pathological hallmark of Alzheimer's disease (AD); however, early detection of AD still presents a challenge. With the assistance of molecular imaging techniques, imaging agents specifically targeting Aβ plaques in the brain may lead to the early diagnosis of AD. Herein, we report the design, synthesis, and evaluation of a series of smart near-infrared fluorescence (NIRF) imaging probes with donor-acceptor architecture bridged by a conjugated π-electron chain for Aβ plaques. The chemical structure of these NIRF probes is completely different from Congo Red and Thioflavin-T. Probes with a longer conjugated π system (carbon-carbon double bond) displayed maximum emission in PBS (>650 nm), which falls in the best range for NIRF probes. These probes were proved to have affinity to Aβ plaques in fluorescent staining of brain sections from an AD patient and double transgenic mice, as well as in an in vitro binding assay using Aβ(1-42) aggregates. One probe with high affinity (K(i) = 37 nM, K(d) = 27 nM) was selected for in vivo imaging. It can penetrate the blood-brain barrier of nude mice efficiently and is quickly washed out of the normal brain. Moreover, after intravenous injection of this probe, 22-month-old APPswe/PSEN1 mice exhibited a higher relative signal than control mice over the same period of time, and ex vivo fluorescent observations confirmed the existence of Aβ plaques. In summary, this probe meets most of the requirements for a NIRF contrast agent for the detection of Aβ plaques both in vitro and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Amyloid Hypothesis of Alzheimer’s Disease: Progress and Problems on the Road to Therapeutics
Hardy, J., & Selkoe, D. J. (2002) · Science · doi:10.1126/science.1072994 · Cited by 13,864
Yung-Chi, C., & Prusoff, W. H. (1973) · Biochemical Pharmacology · doi:10.1016/0006-2952(73)90196-2 · Cited by 12,922
Alzheimer's disease: the amyloid cascade hypothesis
Hardy, J. A., & Higgins, G. A. (1992) · Science · doi:10.1126/science.1566067 · Cited by 7,484
Wong, D. F., Rosenberg, P. B., Zhou, Y., Kumar, A., Raymont, V., Ravert, H. T., Dannals, R. F., Nandi, A., Brašić, J. R., Ye, W., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069088 · Cited by 684
Cited by
Yang, J., Yin, W., Van, R., Yin, K., Wang, P., Zheng, C., Zhu, B., Ran, K., Zhang, C., Kumar, M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17783-4 · Cited by 123
Li, Y., Xu, D., Ho, S.-L., Li, H.-W., Yang, R., & Wong, M. S. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.047 · Cited by 102
Current trends in blood biomarker detection and imaging for Alzheimer’s disease
Hu, S., Yang, C., & Luo, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114278 · Cited by 84
Cui, Z., Bu, W., Fan, W., Zhang, J., Ni, D., Liu, Y., Wang, J., Liu, J., Yao, Z., & Shi, J. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.06.056 · Cited by 83
Near-infrared II theranostic agents for the diagnosis and treatment of Alzheimer’s disease
Zhou, C., Zeng, F., Yang, H., Liang, Z., Xu, G., Li, X., Liu, X., & Yang, J. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06690-1 · Cited by 14
Metadata
- Authors
- Cui, M., Ono, M., Watanabe, H., Kimura, H., Liu, B., & Saji, H.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-20
- Volume
- 136
- Issue
- 9
- Pages
- 3388-3394
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1986291736
- Cited by
- 282
- References
- 4
- FWCI
- 14.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.