The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Oriented Gold Nanoparticle Aggregation for Colorimetric Sensors with Surprisingly High Analytical Figures of Merit
Abstract
The common drawbacks of current colorimetric sensors using gold nanoparticle aggregation is its relatively low sensitivity and narrow dynamic range, which restrict their application in real sample analysis when competing with other analytical techniques such as fluorescence and chemiluminescence. In this article, we demonstrate a novel strategy to construct colorimetric sensors based on gold nanoparticle aggregation. Unlike the conventional colorimetric sensors which cause the formation of large nanoparticle aggregates, in our strategy, dimers are selectively formed upon target binding, which results in significantly improved long-term stability and a more than 2 orders of magnitude wider dynamic range of detection than that of the conventional colorimetric sensors. In addition, a strategy to minimize the interparticle gap through the formation of a Y-shaped DNA duplex enables to increase the limit of detection by 10,000 times. The analytical figures of merit of the proposed sensor are comparable to those of the fluorescence-based sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
A DNA-based method for rationally assembling nanoparticles into macroscopic materials
Mirkin, C. A., Letsinger, R. L., Mucic, R. C., & Storhoff, J. J. (1996) · Nature · doi:10.1038/382607a0 · Cited by 6,683
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Ghosh, S. K., & Pal, T. (2007) · Chemical Reviews · doi:10.1021/cr0680282 · Cited by 2,782
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Gold Nanoparticles in Biology: Beyond Toxicity to Cellular Imaging
Murphy, C. J., Gole, A. M., Stone, J. W., Sisco, P. N., Alkilany, A. M., Goldsmith, E. C., & Baxter, S. C. (2008) · Accounts of Chemical Research · doi:10.1021/ar800035u · Cited by 1,807
Biological applications of gold nanoparticles
Sperling, R. A., Rivera Gil, P., Zhang, F., Zanella, M., & Parak, W. J. (2008) · Chemical Society Reviews · doi:10.1039/b712170a · Cited by 1,799
Cited by
Surface plasmon resonance in gold nanoparticles: a review
Amendola, V., Pilot, R., Frasconi, M., Maragò, O. M., & Iatì, M. A. (2017) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/aa60f3 · Cited by 1,905
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Gold nanoparticle-based colorimetric biosensors
Aldewachi, H., Chalati, T., Woodroofe, M. N., Bricklebank, N., Sharrack, B., & Gardiner, P. (2018) · Nanoscale · doi:10.1039/c7nr06367a · Cited by 634
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
DNA Functional Materials Assembled from Branched DNA: Design, Synthesis, and Applications
Dong, Y., Yao, C., Zhu, Y., Yang, L., Luo, D., & Yang, D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00294 · Cited by 533
Chen, J., Huang, Y., Kannan, P., Zhang, L., Lin, Z., Zhang, J., Chen, T., & Guo, L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03735 · Cited by 464
Self-citationStrategies for enhancing the sensitivity of plasmonic nanosensors
Guo, L., Jackman, J. A., Yang, H.-H., Chen, P., Cho, N.-J., & Kim, D.-H. (2015) · Nano Today · doi:10.1016/j.nantod.2015.02.007 · Cited by 415
Self-citationEmerging advances in nanomedicine with engineered gold nanostructures
Webb, J. A., & Bardhan, R. (2014) · Nanoscale · doi:10.1039/c3nr05112a · Cited by 324
Unexpected Chirality of Nanoparticle Dimers and Ultrasensitive Chiroplasmonic Bioanalysis
Wu, X., Xu, L., Liu, L., Ma, W., Yin, H., Kuang, H., Wang, L., Xu, C., & Kotov, N. A. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4095445 · Cited by 305
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics
Tang, L., & Li, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00282 · Cited by 299
Supraparticles: Functionality from Uniform Structural Motifs
Wintzheimer, S., Granath, T., Oppmann, M., Kister, T., Thai, T., Kraus, T., Vogel, N., & Mandel, K. (2018) · ACS Nano · doi:10.1021/acsnano.8b00873 · Cited by 253
Metadata
- Authors
- Guo, L., Xu, Y., Ferhan, A. R., Chen, G., & Kim, D.-H.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-08
- Volume
- 135
- Issue
- 33
- Pages
- 12338-12345
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2318876210
- Cited by
- 342
- References
- 51
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.