The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Solvothermal Preparation of an Electrocatalytic Metalloporphyrin MOF Thin Film and its Redox Hopping Charge-Transfer Mechanism
Abstract
A thin film of a metalloporphyrin metal-organic framework consisting of [5,10,15,20-(4-carboxyphenyl)porphyrin]Co(III) (CoTCPP) struts bound by linear trinuclear Co(II)-carboxylate clusters has been prepared solvothermally on conductive fluorine-doped tin oxide substrates. Characterization of this mesoporous thin film material, designated as CoPIZA/FTO, which is equipped with large cavities and access to metal active sites, reveals an electrochemically active material. Cyclic voltammetry displays a reversible peak with E(1/2) at -1.04 V vs ferrocyanide attributed to the (Co(III/II)TCPP)CoPIZA redox couple and a quasi-reversible peak at -1.45 V vs ferrocyanide, which corresponds to the reduction of (Co(II/I)TCPP)CoPIZA. Analysis of the spectroelectrochemical response for the (Co(II/I)TCPP)CoPIZA redox couple revealed non-Nernstian reduction with a nonideality factor of 2 and an E(1/2) of -1.39 V vs ferrocyanide. The film was shown to retain its structural integrity with applied potential, as was demonstrated spectroelectrochemically with maintenance of isosbestic points at 430, 458, and 544 nm corresponding to the (Co(III/II)TCPP)CoPIZA transition and at 390 and 449 nm corresponding to the (Co(II/I)TCPP)CoPIZA transition. The mechanism of charge transport through the film is proposed to be a redox hopping mechanism, which is supported by both cyclic voltammetry and spectroelectrochemistry. A fit of the time-dependent spectroelectrochemical data to a modified Cottrell equation gave an apparent diffusion coefficient of 7.55 (±0.05) × 10(-14) cm(2)/s for ambipolar electron and cation transport throughout the film. Upon reduction of the metalloporphyrin struts to (Co(I)TCPP)CoPIZA, the CoPIZA thin film demonstrated catalytic activity for the reduction of carbon tetrachloride.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of X-Ray Photoelectron Spectroscopy
Moulder, J. F. (1995) · Medical Entomology and Zoology · Cited by 23,662
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Eddaoudi, M., Kim, J., Rosi, N., Vodak, D., Wachter, J., O'Keeffe, M., & Yaghi, O. M. (2002) · Science · doi:10.1126/science.1067208 · Cited by 8,132
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Carbon Dioxide Capture in Metal–Organic Frameworks
Sumida, K., Rogow, D. L., Mason, J. A., McDonald, T. M., Bloch, E. D., Herm, Z. R., Bae, T.-H., & Long, J. R. (2012) · Chemical Reviews · doi:10.1021/cr2003272 · Cited by 6,408
Hybrid porous solids: past, present, future
Férey, G. (2008) · Chem. Soc. Rev. · doi:10.1039/b618320b · Cited by 5,822
Hydrogen Storage in Microporous Metal-Organic Frameworks
Rosi, N. L., Eckert, J., Eddaoudi, M., Vodak, D. T., Kim, J., O'Keeffe, M., & Yaghi, O. M. (2003) · Science · doi:10.1126/science.1083440 · Cited by 4,846
Enantioselective catalysis with homochiral metal–organic frameworks
Ma, L., Abney, C., & Lin, W. (2009) · Chemical Society Reviews · doi:10.1039/b807083k · Cited by 3,109
Gouterman, M. (1961) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(61)90236-3 · Cited by 2,227
Caskey, S. R., Wong-Foy, A. G., & Matzger, A. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8036096 · Cited by 1,815
Cited by
Covalent organic frameworks comprising cobalt porphyrins for catalytic CO 2 reduction in water
Lin, S., Diercks, C. S., Zhang, Y.-B., Kornienko, N., Nichols, E. M., Zhao, Y., Paris, A. R., Kim, D., Yang, P., Yaghi, O. M., et al. (2015) · Science · doi:10.1126/science.aac8343 · Cited by 2,644
Electrically Conductive Metal–Organic Frameworks
Xie, L. S., Skorupskii, G., & Dincă, M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00766 · Cited by 1,999
Electrically Conductive Porous Metal–Organic Frameworks
Sun, L., Campbell, M. G., & Dincă, M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201506219 · Cited by 1,901
Metal–Organic Framework-Based Catalysts with Single Metal Sites
Wei, Y.-S., Zhang, M., Zou, R., & Xu, Q. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00757 · Cited by 1,233
Metal–Organic Frameworks for Electrocatalytic Reduction of Carbon Dioxide
Kornienko, N., Zhao, Y., Kley, C. S., Zhu, C., Kim, D., Lin, S., Chang, C. J., Yaghi, O. M., & Yang, P. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b08212 · Cited by 1,158
Hod, I., Sampson, M. D., Deria, P., Kubiak, C. P., Farha, O. K., & Hupp, J. T. (2015) · ACS Catalysis · doi:10.1021/acscatal.5b01767 · Cited by 765
Defective Metal‐Organic Frameworks
Dissegna, S., Epp, K., Heinz, W. R., Kieslich, G., & Fischer, R. A. (2018) · Advanced Materials · doi:10.1002/adma.201704501 · Cited by 728
Liu, J., & Wöll, C. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00315c · Cited by 698
Applications of Metal–Organic‐Framework‐Derived Carbon Materials
Yang, W., Li, X., Li, Y., Zhu, R., & Pang, H. (2019) · Advanced Materials · doi:10.1002/adma.201804740 · Cited by 539
Li, G., Zhao, S., Zhang, Y., & Tang, Z. (2018) · Advanced Materials · doi:10.1002/adma.201800702 · Cited by 521
Metal–organic frameworks for electrocatalysis
Liao, P.-Q., Shen, J.-Q., & Zhang, J.-P. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.09.001 · Cited by 476
Metal–organic framework materials for light-harvesting and energy transfer
So, M. C., Wiederrecht, G. P., Mondloch, J. E., Hupp, J. T., & Farha, O. K. (2015) · Chemical Communications · doi:10.1039/c4cc09596k · Cited by 473
Exploiting redox activity in metal–organic frameworks: concepts, trends and perspectives
D'Alessandro, D. M. (2016) · Chemical Communications · doi:10.1039/c6cc00805d · Cited by 368
MOF-based materials for photo- and electrocatalytic CO2 reduction
Li, X., & Zhu, Q.-L. (2020) · EnergyChem · doi:10.1016/j.enchem.2020.100033 · Cited by 366
Redox-active metal–organic frameworks for energy conversion and storage
Calbo, J., Golomb, M. J., & Walsh, A. (2019) · Journal of Materials Chemistry A · doi:10.1039/c9ta04680a · Cited by 321
Electronic Devices Using Open Framework Materials
Allendorf, M. D., Dong, R., Feng, X., Kaskel, S., Matoga, D., & Stavila, V. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00033 · Cited by 315
Metal–organic frameworks for electrochemical applications
Liu, W., & Yin, X.-B. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.07.011 · Cited by 260
Metadata
- Authors
- Ahrenholtz, S. R., Epley, C. C., & Morris, A. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-28
- Volume
- 136
- Issue
- 6
- Pages
- 2464-2472
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2326096459
- Cited by
- 350
- References
- 45
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.