Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Terminal Protection of Small-Molecule-Linked DNA for Sensitive Electrochemical Detection of Protein Binding via Selective Carbon Nanotube Assembly

Wu, Zhan, Zhen, Zhen, Jiang, Jian-Hui, Shen, Guo-Li, Yu, Ru-Qin·2009·Journal of the American Chemical Society

Abstract

Small-molecule-linked DNA has emerged as a versatile tool for the interaction assay between small organic molecules and their protein receptors. We report herein the proof-of-principle of a terminal protection assay of small-molecule-linked DNA. This assay is based on our new finding that single-stranded DNA (ssDNA) terminally tethered to a small molecule is protected from the degradation by exonuclease I (Exo I) when the small molecule moiety is bound to its protein target. This finding translates the binding of small molecules to proteins into the presence of a specific DNA sequence, which enables us to probe the interaction between small organic molecules and their protein targets using various DNA sequence amplification and detection technologies. On the basis of selective assembly of single-walled carbon nanotubes (SWNTs) with surface-tethered small-molecule-linked ssDNA not protected by protein binding, a novel electrochemical strategy for terminal protection assay has been developed. Through detecting the redox signal mediated by SWNT assembly on a 16-mercaptohexadecanoic acid-blocked electrode, this strategy is able to ensure substantial signal amplification and a low background current. This strategy is demonstrated for quantitative analysis of the interaction of folate with a tumor biomarker of folate receptor (FR), and a detection limit of 3 pM FR is readily achieved with desirable specificity and sensitivity, indicating that the terminal protection assay can offer a promising platform for small molecule-protein interaction studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja9038054

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 206

Metadata

Authors
Wu, Z., Zhen, Z., Jiang, J.-H., Shen, G.-L., & Yu, R.-Q.
Venue
Journal of the American Chemical Society
Published
2009-08-05
Volume
131
Issue
34
Pages
12325-12332
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2090650502
Cited by
206
References
3
FWCI
5.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terminal Protection of Small-Molecule-Linked DNA for Sensitive Electrochemical Detection of Protein Binding via Selective Carbon Nanotube Assembly. https://app.cochat.ai/papers/10.1021/ja9038054
The paper
Wu, Z., Zhen, Z., Jiang, J.-H., Shen, G.-L., & Yu, R.-Q. (2009). Terminal Protection of Small-Molecule-Linked DNA for Sensitive Electrochemical Detection of Protein Binding via Selective Carbon Nanotube Assembly. Journal of the American Chemical Society. https://doi.org/10.1021/ja9038054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.