The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hydrogen/Deuterium Exchange Mass Spectrometry with Top-Down Electron Capture Dissociation for Characterizing Structural Transitions of a 17 kDa Protein
Abstract
Amide H/D exchange (HDX) mass spectrometry (MS) is widely used for protein structural studies. Traditionally, this technique involves protein labeling in D(2)O, followed by acid quenching, proteolytic digestion, and analysis of peptide deuteration levels by HPLC/MS. There is great interest in the development of alternative HDX approaches involving the top-down fragmentation of electrosprayed protein ions, instead of relying on enzymatic cleavage and solution-phase separations. A number of recent studies have demonstrated that electron capture dissociation (ECD) results in fragmentation of gaseous protein ions with little or no H/D scrambling. However, the successful application of this approach for in-depth protein conformational studies has not yet been demonstrated. The current work uses horse myoglobin as a model system for assessing the suitability of HDX-MS with top-down ECD for experiments of this kind. It is found that ECD can pinpoint the locations of protected amides with an average resolution of less than two residues for this 17 kDa protein. Native holo-myoglobin (hMb) shows considerable protection from exchange in all of its helices, whereas loops are extensively deuterated. Fraying is observable at some helix termini. Removal of the prosthetic heme group from hMb produces apo-myoglobin (aMb). Both hMb and aMb share virtually the same HDX protection pattern in helices A-E, whereas helix F is unfolded in aMb. In addition, destabilization is evident for some residues close to the beginning of helix G, the end of helix H, and the C-terminus of the protein. The structural changes reported herein are largely consistent with earlier NMR data for sperm whale myoglobin, although small differences between the two systems are evident. Our findings demonstrate that the level of structural information obtainable with top-down ECD for small to medium-sized proteins considerably surpasses that of traditional HDX-MS experiments, while at the same time greatly reducing undesired amide back exchange.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Lanman, J., Lam, T. T., Barnes, S., Sakalian, M., Emmett, M. R., Marshall, A. G., & Prevelige, P. E. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)01245-7 · Cited by 206
Cited by
Hydrogen exchange mass spectrometry for studying protein structure and dynamics
Konermann, L., Pan, J., & Liu, Y.-H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00113a · Cited by 838
Self-citationMasson, G. R., Burke, J. E., Ahn, N. G., Anand, G. S., Borchers, C., Brier, S., Bou-Assaf, G. M., Engen, J. R., Englander, S. W., Faber, J., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0459-y · Cited by 729
Self-citationApproaching infinite affinity through engineering of peptide–protein interaction
Keeble, A. H., Turkki, P., Stokes, S., Khairil Anuar, I. N. A., Rahikainen, R., Hytönen, V. P., & Howarth, M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1909653116 · Cited by 379
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Differential hydrogen/deuterium exchange mass spectrometry analysis of protein–ligand interactions
Chalmers, M. J., Busby, S. A., Pascal, B. D., West, G. M., & Griffin, P. R. (2011) · Expert Review of Proteomics · doi:10.1586/epr.10.109 · Cited by 252
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Self-citationIon Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
LeDuc, R. D., Fellers, R. T., Early, B. P., Greer, J. B., Thomas, P. M., & Kelleher, N. L. (2014) · Journal of Proteome Research · doi:10.1021/pr401277r · Cited by 85
Metadata
- Authors
- Pan, J., Han, J., Borchers, C. H., & Konermann, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-11
- Volume
- 131
- Issue
- 35
- Pages
- 12801-12808
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2088461621
- Cited by
- 201
- References
- 3
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.