Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Multiply-charged cations derived from electrospray of bovine ubiquitin and horse skeletal muscle apomyoglobin have been subjected to reactions with anions derived from glow discharge ionization of perfluoro-1,3-dimethylcyclohexane. The results are compared with data obtained from proton transfer reactions with strong gaseous neutral bases. Ion/ion reaction rates are shown to be linearly related to the square of the charge on the protein ion, as expected based on a simple capture collision model. Cationic products with charge as low as +1 could be readily formed via ion/ion reactions, whereas efforts to produce such low charge states via ion/molecule reactions have proved unsuccessful. Ion/ion proton transfer reactions appear to be an effective means of reducing charge on highly charged proteins to arbitrarily low charge states. In addition to proton transfer, ion/ion recombination has also been observed. The propensity for proton transfer versus anion attachment to the cation is highly dependent upon the identity of the anion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a multiply charged cation is let to react with a singly charged anion (typically originated from a perfluorinated molecule) to generate a cation with reduced charge state and a neutral molecule (that produces no signal during m/z analysis)”
From Proton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms (2019) · cites this paper as [29]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Parametrization of the ion–polar molecule collision rate constant by trajectory calculations
Su, T., & Chesnavich, W. J. (1982) · The Journal of Chemical Physics · doi:10.1063/1.442828 · Cited by 1,403
Reactions of Gaseous Molecule Ions with Gaseous Molecules. V. Theory
Gioumousis, G., & Stevenson, D. P. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744477 · Cited by 1,375
Dobbins, R. A., Mohammed, K., & Sullivan, D. A. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555819 · Cited by 1,277
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
(1979) · Elsevier eBooks · doi:10.1016/c2013-0-07190-3 · Cited by 584
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
Research works printed but not linked: 26
- Yamashita M., 1984, J. Phys. Chem., 88, 4675
- Aleksandrov M. L., 1984, Dokl. Phys. Chem. (Engl.), 277, 575
- Wong S. F., 1988, J. Phys. Chem., 92, 550
- Meng C. K., 1988, Z. Phys. D.: At. Mol. Clusters, 10, 368
- Fenn J. B., 1990, Science, 246, 71
- Smith R. D., 1990, Anal. Chem., 62, 899
- Fenn J. B., 1990, Mass Spectrom. Rev., 9, 70
- Smith R. D., 1990, Anal. Chem., 62, 899
- Loo J. A., 1991, Rapid Commun. Mass Spectrom., 5, 105
- Loo J. A., 1990, Rapid Commun. Mass Spectrom., 4, 207
- Leblanc J. C. Y., 1991, Org. Mass Spectrom., 26, 839
- Cheng X., 1995, Anal. Chem., 67, 593
- Loo R. R. O., 1992, Rapid Commun. Mass Spectrom., 6, 165
- Loo R. R. O., 1994, J. Am. Soc. Mass Spectrom., 5, 220
- Ogorzalek-Loo R. R., 1994, J. Am. Soc. Mass Spectrom., 5, 1071
- McLuckey S. A., 1995, Modern Mass Spectrometry: Practical Aspects of Ion Trap Mass Spectrometry, 2
- McLuckey S. A., 1991, Anal. Chem., 63, 383
- Kaiser R. E., 1989, Rapid Commun. Mass Spectrom., 3, 53
- Kaiser R. E., 1989, Rapid Commun. Mass Spectrom., 3, 229
- Langevin P. M., 1905, Ann. Chim. Phys., 5, 245
- Roth L. M., 1991, Mass Spectrom. Rev., 10, 328
- Petrie S., 1993, J. Am. Chem. Soc., 115, 6294
- Javahery G., 1993, J. Am. Chem. Soc., 115, 6301
- Loo R. R. O., 1991, J. Phys. Chem., 95, 6415, 10.1021/j100170a007 · DOI
- Loo R. R. O., 1992, J. Am. Soc. Mass Spectrom., 3, 705
- Langford M. L., 1995, Practical Aspects of Ion Trap Mass Spectrometry
Cited by
Items 201–217 of 217
Li, L., Yang, S. H., Vidová, V., Rice, E. M., Wijeratne, A. B., Havlı́ček, V., & Schug, K. A. (2015) · European Journal of Mass Spectrometry · doi:10.1255/ejms.1364 · Cited by 1
Aldehyde Complexes with Protonated Peptides in the Gas Phase
Shi, X. E., Ren, J., & Parks, J. H. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp112037a · Cited by 1
Ion/Ion Reactions in Electrodynamic Ion Traps
Liu, J., & McLuckey, S. A. (2009) · CRC Press eBooks · doi:10.1201/9781420083743-c1 · Cited by 1
Self-citationMethods for Multi-Stage Ion Processing Involving Ion/Ion Chemistry in a Quadrupole Linear Ion Trap
McAlister, G. C., & Coon, J. J. (2009) · CRC Press eBooks · doi:10.1201/9781420083743-c3 · Cited by 1
Soyk, M. W. (2008) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-1176 · Cited by 1
Simple capture collision model for cation–anion reactions in the gas phase
Turulski, J., Niedzielski, J., & Su, T. A. (2001) · Chemical Physics · doi:10.1016/s0301-0104(00)00400-6 · Cited by 1
Hyphenated Applications of Mass Spectrometry for the Analysis of Biological Compounds
Morast, D. (2012) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-121 · Cited by 1
Extending the frontiers of mass spectrometric instrumentation and methods
Schieffer, G. M., & USDOE Office of Science (SC) (2010) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1037883 · Cited by 1
A linear ion trap for biological agent detection and identification
Griffin, M. T., & McLuckey, S. A. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.541453
Self-citationLi, L. (2014) · UTA ResearchCommons (University of Texas Arlington)
Negative Ion Electron Capture Dissociation (niECD): A Novel Tandem Mass Spectrometric Technique.
Wang, N. (2014) · Deep Blue (University of Michigan) · Cited by 1
Going, C. C. (2015) · eScholarship (California Digital Library)
Analytical applications of gas-phase ion chemistry enabled by mass spectrometry
Kang, W.-Y., & Prentice, B. M. (2026) · Analytical Methods · doi:10.1039/d5ay00535c
Gas phase charge reduction for improved protein characterization by mass spectrometry
Tennakoon, S. C., Amunugama, L., & Shaw, J. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.346036
Veth, T. S., Sutherland, E., Hinkle, J. D., Bergen, D., Melani, R. D., McAlister, G. C., Mullen, C., & Riley, N. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.27.747529
“29 Charge reduction has been valued for its ability to simplify spectral interpretation for decades 30 – 43 , and as proton-transfer charge reduction (PTCR) has become more widely accessible on commercial instruments 44 – 49 , it has emerged as a potentially useful tool for charting glycoproteoform…”
Polák, M., Anderson, L. C., Håkansson, H., Hendrickson, C. L., & Weisbrod, C. R. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c04013
Unifying N- and O-glycopeptide dissociation methods with expedient electron transfer dissociationPreprint
Schramm, H. M., Veth, T. S., Hinkle, J. D., Huang, J., Bergen, D., Melani, R. D., McAlister, G. C., Mullen, C., & Riley, N. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.12.758703
“As described by McLuckey, Stephenson, and co-workers 70 – 73 , the ion-ion capture rate coefficient is defined by Equation 2: where is the relative velocity of the oppositely charged ions, µ is the reduced mass of the collision partners, and z 1 and z 2 are the charges of the reaction partners,…”
Metadata
- Authors
- Stephenson, J. L., & McLuckey, S. A.
- Affiliations
- Oak Ridge National Laboratory (US)
- ORCID
- McLuckey, Scott A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 118
- Issue
- 31
- Pages
- 7390-7397
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2072391178
- Cited by
- 215
- References
- 57
- Citations by year
- 2026: 6 · 2025: 6 · 2024: 11 · 2023: 9 · 2022: 10 · 2021: 6 · 2020: 4 · 2019: 5 · 2018: 2 · 2017: 5 · 2016: 3 · 2015: 8 · 2014: 6 · 2013: 2 · 2012: 6
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Chemical Society (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
- Keywords
- ion/ion reactions, proton transfer, ubiquitin, apomyoglobin, ion-ion recombination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.