The DOI matches its Crossref record.
Probing Resistance to Protein Adsorption of Oligo(ethylene glycol)-Terminated Self-Assembled Monolayers by Scanning Force Microscopy
Abstract
Functionalized scanning force microscope (SFM) probes were used to investigate and to mimic the interaction between fibrinogen and self-assembled monolayers (SAMs) of methoxytri(ethylene glycol) undecanethiolates −S(CH 2 ) 11 (OCH 2 CH 2 ) 3 OCH 3 (EG3-OMe) on gold and silver surfaces. The SAMs on gold are resistant to protein adsorption, whereas the films on silver adsorb variable amounts of fibrinogen. Experiments were performed with both charged and hydrophobic tips as models for local protein structures to determine the influence of these parameters on the interaction with the SAMs. A striking difference between the two monolayers was established when the forces were measured in an aqueous environment with hydrophobic probes. While a long-range attractive hydrophobic interaction was observed for the EG3-OMe on silver, a repulsive force was measured for EG3-OMe on gold. The strong dependence of the repulsive force for the EG3-OMe-gold system upon the solution ionic strength suggests that this interaction has a significant electrostatic contribution. The observed differences are attributed to the distinct molecular conformations of the oligo(ethylene glycol) tails on the gold-supported (helical) and silver-supported (“all-trans”) monolayers. A comparison of the force/distance curves for the EG3-OMe SAMs with those measured under identical conditions on end-grafted poly(ethylene glycol) (PEG 2000) on gold further emphasizes that the nature of the repulsive forces originating from the short-chain oligomers is unique and not related to a “steric repulsion” effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Noncovalent functionalization of carbon nanotubes for highly specific electronic biosensors
Chen, R. J., Bangsaruntip, S., Drouvalakis, K. A., Wong Shi Kam, N., Shim, M., Li, Y., Kim, W., Utz, P. J., & Dai, H. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0837064100 · Cited by 1,442
Herrwerth, S., Eck, W., Reinhardt, S., & Grunze, M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034820y · Cited by 697
Self-citationProtein Resistance of Titanium Oxide Surfaces Modified by Biologically Inspired mPEG−DOPA
Dalsin, J. L., Lin, L., Tosatti, S., Vörös, J., Textor, M., & Messersmith, P. B. (2005) · Langmuir · doi:10.1021/la048626g · Cited by 455
Luk, Y.-Y., Kato, M., & Mrksich, M. (2000) · Langmuir · doi:10.1021/la0004653 · Cited by 414
Effect of Surface Wettability on the Adhesion of Proteins
Sethuraman, A., Han, M., Kane, R. S., & Belfort, G. (2004) · Langmuir · doi:10.1021/la049454q · Cited by 344
Zheng, J., Li, L., Tsao, H.-K., Sheng, Y.-J., Chen, S., & Jiang, S. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.059428 · Cited by 340
Flexible phenylalanine-glycine nucleoporins as entropic barriers to nucleocytoplasmic transport
Lim, R. Y. H., Huang, N.-P., Köser, J., Deng, J., Lau, K. H. A., Schwarz-Herion, K., Fahrenkrog, B., & Aebi, U. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603521103 · Cited by 273
Surface strategies for control of neuronal cell adhesion: A review
Roach, P., Parker, T., Gadegaard, N., & Alexander, M. R. (2010) · Surface Science Reports · doi:10.1016/j.surfrep.2010.07.001 · Cited by 180
Metadata
- Authors
- Feldman, K., Hähner, G., Spencer, N. D., Harder, P., & Grunze, M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-15
- Volume
- 121
- Issue
- 43
- Pages
- 10134-10141
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2028362286
- Cited by
- 279
- References
- 0
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.