The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
Abstract
There are urgent needs for sensing devices capable of distinguishing between episodes of opioid overdose and nerve agent poisoning. This work presents a wearable microneedle sensor array for minimally invasive continuous electrochemical detection of opioid (OPi) and organophosphate (OP) nerve agents on a single patch platform. The new multimodal microneedle sensor array relies on unmodified and organophosphorus hydrolase (OPH) enzyme-modified carbon paste (CP) microneedle electrodes for square wave voltammetric (SWV) detection of the fentanyl and nerve agent targets, respectively. Such real-time simultaneous sensing provides distinct unique information, along with attractive analytical performance, including high sensitivity, selectivity, and stability, for real-time on-body OPi-OP analysis. The patch represents the first sensing device capable of continuously monitoring fentanyl down to the nanomolar level through a nanomaterial-based multilayered surface architecture. Applicability of the sensor array toward opioids screening is demonstrated for morphine and norfentanyl. Successful OPi-OP detection conducted in a skin-mimicking phantom gel demonstrates the suitability of the device for rapid on-body sensing. Such progress toward continuous minimally invasive transdermal analysis of drugs of abuse and nerve agents holds promise for rapid countermeasures for protecting soldiers, civilians, and healthcare personnel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Self-citationThe economic burden of prescription opioid overdose, abuse and dependence in the United States, 2013
Florence, C. S., Zhou, C., Luo, F., & Xu, L. (2016) · Medical Care · doi:10.1097/mlr.0000000000000625 · Cited by 1,152
Teymourian, H., Moonla, C., Tehrani, F., Vargas, E., Aghavali, R., Barfidokht, A., Tangkuaram, T., Mercier, P. P., Dassau, E., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05109 · Cited by 278
Self-citation
Cited by
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Self-citationA wireless patch for the monitoring of C-reactive protein in sweat
Tu, J., Min, J., Song, Y., Xu, C., Li, J., Moore, J., Hanson, J., Hu, E., Parimon, T., Wang, T.-Y., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01059-5 · Cited by 395
Zn‐MOF Encapsulated Antibacterial and Degradable Microneedles Array for Promoting Wound Healing
Yao, S., Chi, J., Wang, Y., Zhao, Y., Luo, Y., & Wang, Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100056 · Cited by 325
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Self-citationWearable Pressure Sensors Based on MXene/Tissue Papers for Wireless Human Health Monitoring
Yang, L., Wang, H., Yuan, W., Li, Y., Gao, P., Tiwari, N., Chen, X., Wang, Z., Niu, G., & Cheng, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22001 · Cited by 283
Metadata
- Authors
- Mishra, R. K., Goud, K. Y., Li, Z., Moonla, C., Mohamed, M. A., Tehrani, F., Teymourian, H., & Wang, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-03-22
- Volume
- 142
- Issue
- 13
- Pages
- 5991-5995
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W3012875080
- Cited by
- 238
- References
- 3
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.