Cited by 395Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsBiosensors and Analytical Detection

A wireless patch for the monitoring of C-reactive protein in sweat

Open access
Tu, Jiaobing, Min, Jihong, Song, Yu, Xu, Changhao, Li, Jiahong, Moore, Jeff, Hanson, Justin, Hu, Erin +8 more·2023·Nature Biomedical Engineering

Abstract

The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-023-01059-5

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Javey group, Gao group and Wang group focused on electrochemical biosensing of sweat using various wearable sweat patches for sweat rate, L-Dopa, C-reactive protein, cortisol, ketone, glucose, and therapeutic drugs.

    “Javey group, Gao group and Wang group also focused on electrochemical biosensing of sweat using various wearable sweat patches for sweat rate [30], L-Dopa [138,139], and C-reactive protein [140], cortisol [141,142], ketone [143], glucose [144], and therapeutic drugs [145].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Tu, J., Min, J., Song, Y., Xu, C., Li, J., Moore, J., Hanson, J., Hu, E., Parimon, T., Wang, T.-Y., Davoodi, E., Chou, T.-F., Chen, P., Hsu, J. J., Rossiter, H. B., & Gao, W.
Affiliations
  • California Institute of Technology (US)
  • The Lundquist Institute (US)
  • University of California, Los Angeles (US)
  • Cedars-Sinai Medical Center (US)
Corresponding author
Gao, Wei
Venue
Nature Biomedical Engineering
Published
2023-06-22
Volume
7
Issue
10
Pages
1293-1306
ISSN
2157-846X (ISSN-L)
OpenAlex
W4381612623
Cited by
395
References
61
Citations by year
2026: 99 · 2025: 171 · 2024: 103 · 2023: 22
FWCI
29.34
Type
journal article
Language
en
Open access
Locations
  • Nature Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • American Heart Association (19TPA34850157)
  • U.S. Department of Health & Human Services | National Institutes of Health (R21DK13266, T32EB027629, 1S10OD02001301)
  • National Science Foundation (2145802)
  • United States Department of Defense | United States Navy | Office of Naval Research (N00014-21-1-2483, N00014-21-1-2845)
  • Tobacco-Related Disease Research Program (T31IP1666)
  • Alfred P. Sloan Foundation
  • Agency for Science, Technology and Research
  • Cedars-Sinai Medical Center (Technology Ventures Internal Project)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
C-reactive protein, sweat monitoring, electrochemical biosensor, iontophoresis, anti-CRP antibody, gold nanoparticles, point-of-care monitoring, chronic obstructive pulmonary disease, inflammatory markers
MeSH terms
Wearable Electronic Devices, C-Reactive Protein, Gold, Humans, Monitoring, Physiologic, Sweat, Biomarkers, Metal Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›