The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dual-Mode Ultrasensitive Quantification of MicroRNA in Living Cells by Chiroplasmonic Nanopyramids Self-Assembled from Gold and Upconversion Nanoparticles
Abstract
Chiral self-assembled nanomaterials with biological applications have attracted great interest. In this study, DNA-driven gold-upconversion nanoparticle (Au-UCNP) pyramids were fabricated to detect intracellular microRNA (miRNA) in real time. The Au-UCNP pyramids are doubly optically active, displaying strong plasmonic circular dichroism (CD) at 521 nm and significant luminescence in 500-600 nm, and therefore can be monitored by both of them. CD will decrease while the luminescence intensity increases in the presence of miRNA. The experimental results show that the CD intensity had an outstanding linear range from 0.073 to 43.65 fmol/10 μg(RNA) and a limit of detection (LOD) of 0.03 fmol/10 μg(RNA), whereas the luminescence intensity ranged from 0.16 to 43.65 fmol/10 μg(RNA) with a LOD of 0.12 fmol/10 μg(RNA). These data indicate that the CD signal is much more sensitive to the concentration of miRNA than the luminescent signal, which is attributed to the strong CD intensity arising from the spin angular momentum of the photon interaction with chiral nanostructures and the plasmonic enhancement of the intrinsic chirality of DNA molecules in the pyramids. This approach opens up a new avenue to the ultrasensitive detection and quantification of miRNA in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MicroRNAs: Target Recognition and Regulatory Functions
Bartel, D. P. (2009) · Cell · doi:10.1016/j.cell.2009.01.002 · Cited by 20,068
Devulapally, R., Sekar, N. M., Sekar, T. V., Foygel, K., Massoud, T. F., Willmann, J. K., & Paulmurugan, R. (2015) · ACS Nano · doi:10.1021/nn507465d · Cited by 260
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationRational Engineering of a Dynamic, Entropy‐Driven DNA Nanomachine for Intracellular MicroRNA Imaging
Liang, C., Ma, P., Liu, H., Guo, X., Yin, B., & Ye, B. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704147 · Cited by 389
Site-selective photoinduced cleavage and profiling of DNA by chiral semiconductor nanoparticles
Sun, M., Xu, L., Qu, A., Zhao, P., Hao, T., Ma, W., Hao, C., Wen, X., Colombari, F. M., de Moura, A. F., et al. (2018) · Nature Chemistry · doi:10.1038/s41557-018-0083-y · Cited by 298
Self-citation
Metadata
- Authors
- Li, S., Xu, L., Ma, W., Wu, X., Sun, M., Kuang, H., Wang, L., Kotov, N. A., & Xu, C.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-29
- Volume
- 138
- Issue
- 1
- Pages
- 306-312
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2197075717
- Cited by
- 464
- References
- 2
- FWCI
- 19.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Mode Ultrasensitive Quantification of MicroRNA in Living Cells by Chiroplasmonic Nanopyramids Self-Assembled from Gold and Upconversion Nanoparticles. https://app.cochat.ai/papers/10.1021/jacs.5b10309
- The paper
- Li, S., Xu, L., Ma, W., Wu, X., Sun, M., Kuang, H., Wang, L., Kotov, N. A., & Xu, C. (2016). Dual-Mode Ultrasensitive Quantification of MicroRNA in Living Cells by Chiroplasmonic Nanopyramids Self-Assembled from Gold and Upconversion Nanoparticles. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.5b10309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.