The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photoacoustic Probes for Ratiometric Imaging of Copper(II)
Abstract
Photoacoustic tomography has emerged as a promising alternative to MRI and X-ray scans in the clinical setting due to its ability to afford high-resolution images at depths in the cm range. However, its utility has not been established in the basic research arena owing to a lack of analyte-specific photoacoustic probes. To this end, we have developed acoustogenic probes for copper(II)-1 and -2 (APC-1 and APC-2, a water-soluble congener) for the chemoselective visualization of Cu(II), a metal ion which plays a crucial role in chronic neurological disorders such as Alzheimer's disease. To detect Cu(II), we have equipped both APCs with a 2-picolinic ester sensing module that is readily hydrolyzed in the presence of Cu(II) but not by other divalent metal ions. Additionally, we designed APC-1 and APC-2 explicitly for ratiometric photoacoustic imaging by using an aza-BODIPY dye scaffold exhibiting two spectrally resolved NIR absorbance bands which correspond to the 2-picolinic ester capped and uncapped phenoxide forms. The normalized ratiometric turn-on responses for APC-1 and APC-2 were 89- and 101-fold, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
Shi, Z., Han, X., Hu, W., Bai, H., Peng, B., Ji, L., Fan, Q., Li, L., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00234h · Cited by 469
Azadipyrromethenes: from traditional dye chemistry to leading edge applications
Ge, Y., & O'Shea, D. F. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00200e · Cited by 354
Metadata
- Authors
- Li, H., Zhang, P., Smaga, L. P., Hoffman, R. A., & Chan, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-11
- Volume
- 137
- Issue
- 50
- Pages
- 15628-15631
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2337585522
- Cited by
- 239
- References
- 1
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoacoustic Probes for Ratiometric Imaging of Copper(II). https://app.cochat.ai/papers/10.1021/jacs.5b10504
- The paper
- Li, H., Zhang, P., Smaga, L. P., Hoffman, R. A., & Chan, J. (2015). Photoacoustic Probes for Ratiometric Imaging of Copper(II). Journal of the American Chemical Society. https://doi.org/10.1021/jacs.5b10504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.