The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Upconversion Nanoprobes for the Ratiometric Luminescent Sensing of Nitric Oxide
Abstract
By taking advantage of the optical properties of upconversion nanoparticles (UCNPs), we have designed a luminescence ratiometric nanosensor for measuring nitric oxide (NO) in biological fluids, live cells, and tissues. This nanoconjugate consists of a UCNP core with two strong fluorescence emission peaks at 540 and 656 nm as the upconversion fluorophore, NO-reactive rhodamine B-derived molecules (RdMs) encapsulated within the mesopores of the mSiO 2 shell, and a β-cyclodextrin (βCD) layer on the exterior of the particle. Reaction of the analyte with the O -phenylenediamine of the RdM induces opening of the spiro-ring and is accompanied by an appearance of a strong rhodamine B (RdB) absorption band between 500 and 600 nm, which has spectral overlap with the green emission (540 nm) of the UCNPs. This results in an increase in the I 656 / I 540 ratio and quantitatively correlates with [NO]. The assay is validated under clean buffer conditions as well as inserum and liver tissue slices obtained from mouse models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Cited by
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Upconversion Luminescence-Activated DNA Nanodevice for ATP Sensing in Living Cells
Zhao, J., Gao, J., Xue, W., Di, Z., Xing, H., Lu, Y., & Li, L. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b11161 · Cited by 361
Gu, B., & Zhang, Q. (2018) · Advanced Science · doi:10.1002/advs.201700609 · Cited by 292
Wang, C., Lin, H., Ge, X., Mu, J., Su, L., Zhang, X., Niu, M., Yang, H., & Song, J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009942 · Cited by 89
Unlocking the NIR‐II AIEgen for High Brightness through Intramolecular Electrostatic Locking
Wang, X., Yang, X., Jiang, G., Hu, Z., Liao, T., Wang, G., Zhang, X., He, X., Zhang, J., Zhang, J., et al. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202404142 · Cited by 44
Self-citation
Metadata
- Authors
- Wang, N., Yu, X., Zhang, K., Mirkin, C. A., & Li, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-05
- Volume
- 139
- Issue
- 36
- Pages
- 12354-12357
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2746891585
- Cited by
- 165
- References
- 1
- FWCI
- 7.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Upconversion Nanoprobes for the Ratiometric Luminescent Sensing of Nitric Oxide. https://app.cochat.ai/papers/10.1021/jacs.7b06059
- The paper
- Wang, N., Yu, X., Zhang, K., Mirkin, C. A., & Li, J. (2017). Upconversion Nanoprobes for the Ratiometric Luminescent Sensing of Nitric Oxide. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.7b06059
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.