The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Rapid Simultaneous Removal of Toxic Anions [HSeO3]−, [SeO3]2–, and [SeO4]2–, and Metals Hg2+, Cu2+, and Cd2+ by MoS42– Intercalated Layered Double Hydroxide
Abstract
We demonstrate fast, highly efficient concurrent removal of toxic oxoanions of Se(VI) (SeO 4 2– ) and Se(IV) (SeO 3 2– /HSeO 3 – ) and heavy metal ions of Hg 2+, Cu 2+, and Cd 2+ by the MoS 4 2– intercalated Mg/Al layered double hydroxide (MgAl-MoS 4 -LDH, abbr. MoS 4 -LDH). Using the MoS 4 -LDH as a sorbent, we observe that the presence of Hg 2+ ions greatly promotes the capture of SeO 4 2–, while the three metal ions (Hg 2+, Cu 2+, Cd 2+ ) enable a remarkable improvement in the removal of SeO 3 2– /HSeO 3 – . For the pair Se(VI)+Hg 2+, the MoS 4 -LDH exhibits outstanding removal rates (>99.9%) for both Hg 2+ and Se(VI), compared to 81% removal for SeO 4 2– alone. For individual SeO 3 2– (without metal ions), 99.1% Se(IV) removal is achieved, while ≥99.9% removals are reached in the presence of Hg 2+, Cu 2+, and Cd 2+ . Simultaneously, the removal rates for these metal ions are also >99.9%, and nearly all concentrations of the elements can be reduced to <10 ppb, a limit acceptable for drinking water. The maximum sorption capacities for individual Se(VI) and Se(IV) are 85 and 294 mg/g, respectively. The 294 mg/g capacity for Se(IV) reaches a record value, placing the MoS 4 -LDH among the highest-capacity selenite adsorbing materials described to date. More interestingly, the presence of metal ions extremely accelerates the capture of the selenium oxoanions because of the reactions of the metal ions with the interlayer MoS 4 2– anions. The sorptions of Se(VI)+Hg and Se(IV)+M (M = Hg 2+, Cu 2+, Cd 2+ ) are exceptionally rapid, showing >99.5% removals for Hg 2+ within 1 min and ∼99.0% removal for Se(VI) within 30 min, as well as >99.5% removals for pairs Cu 2+ and Se(IV) within 10 min, and Cd 2+ and Se(IV) within 30 min. During the sorption of SeO 3 2– /HSeO 3 –, reduction of Se(IV) occurs to Se 0 caused by the S 2– sites in MoS 4 2– . Sorption kinetics for the oxoanions follows a pseudo-second-order model consistent with chemisorption. The intercalated material of MoS 4 -LDH is very promising as a highly effective filter for decontamination of water with toxic Se(IV)/Se(VI) oxoanions along with heavy metals such as Hg 2+, Cd 2+, and Cu 2+ .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ohlendorf, H. M., Hoffman, D. J., Saiki, M. K., & Aldrich, T. W. (1986) · Science of The Total Environment · doi:10.1016/0048-9697(86)90104-x · Cited by 600
Selenate and Selenite Sorption on Iron Oxides An Infrared and Electrophoretic Study
Su, C., & Suarez, D. L. (2000) · Soil Science Society of America Journal · doi:10.2136/sssaj2000.641101x · Cited by 261
Selenium Concentrations in Natural and Environmental Waters
Conde, J. E., & Sanz Alaejos, M. (1997) · Chemical Reviews · doi:10.1021/cr960100g · Cited by 194
Cited by
Wang, L., Hou, D., Cao, Y., Ok, Y. S., Tack, F. M. G., Rinklebe, J., & O'Connor, D. (2020) · Environment International · doi:10.1016/j.envint.2019.105281 · Cited by 396
A review on heavy metal ions adsorption from water by layered double hydroxide and its composites
Feng, X., Long, R., Wang, L., Liu, C., Bai, Z., & Liu, X. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2021.120099 · Cited by 329
Zhang, Q., Bolisetty, S., Cao, Y., Handschin, S., Adamcik, J., Peng, Q., & Mezzenga, R. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201901596 · Cited by 295
Amorphous Carbon Dots and their Remarkable Ability to Detect 2,4,6-Trinitrophenol
Siddique, A. B., Pramanick, A. K., Chatterjee, S., & Ray, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-28021-9 · Cited by 267
Bi, R., Yin, D., Zhang, S., Zhang, R., & Chen, F. (2022) · Applied Clay Science · doi:10.1016/j.clay.2022.106536 · Cited by 29
Metadata
- Authors
- Ma, L., Islam, S. M., Xiao, C., Zhao, J., Liu, H., Yuan, M., Sun, G., Li, H., Ma, S., & Kanatzidis, M. G.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-30
- Volume
- 139
- Issue
- 36
- Pages
- 12745-12757
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2742344561
- Cited by
- 222
- References
- 3
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Simultaneous Removal of Toxic Anions [HSeO3]−, [SeO3]2–, and [SeO4]2–, and Metals Hg2+, Cu2+, and Cd2+ by MoS42– Intercalated Layered Double Hydroxide. https://app.cochat.ai/papers/10.1021/jacs.7b07123
- The paper
- Ma, L., Islam, S. M., Xiao, C., Zhao, J., Liu, H., Yuan, M., Sun, G., Li, H., Ma, S., & Kanatzidis, M. G. (2017). Rapid Simultaneous Removal of Toxic Anions [HSeO3]−, [SeO3]2–, and [SeO4]2–, and Metals Hg2+, Cu2+, and Cd2+ by MoS42– Intercalated Layered Double Hydroxide. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.7b07123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.