The DOI matches its Crossref record.
Influence of Enzyme Quantity and Distribution on the Self-Propulsion of Non-Janus Urease-Powered Micromotors
Abstract
The use of enzyme catalysis to power micro- and nanomachines offers unique features such as biocompatibility, versatility, and fuel bioavailability. Yet, the key parameters underlying the motion behavior of enzyme-powered motors are not completely understood. Here, we investigate the role of enzyme distribution and quantity on the generation of active motion. Two different micromotor architectures based on either polystyrene (PS) or polystyrene coated with a rough silicon dioxide shell (PS@SiO 2 ) were explored. A directional propulsion with higher speed was observed for PS@SiO 2 motors when compared to their PS counterparts. We made use of stochastically optical reconstruction microscopy (STORM) to precisely detect single urease molecules conjugated to the micromotors surface with a high spatial resolution. An asymmetric distribution of enzymes around the micromotor surface was observed for both PS and PS@SiO 2 architectures, indicating that the enzyme distribution was not the only parameter affecting the motion behavior. We quantified the number of enzymes present on the micromotor surface and observed a 10-fold increase in the number of urease molecules for PS@SiO 2 motors compared to PS-based micromotors. To further investigate the number of enzymes required to generate a self-propulsion, PS@SiO 2 particles were functionalized with varying amounts of urease molecules and the resulting speed and propulsive force were measured by optical tracking and optical tweezers, respectively. Surprisingly, both speed and force depended in a nonlinear fashion on the enzyme coverage. To break symmetry for active propulsion, we found that a certain threshold number of enzymes molecules per micromotor was necessary, indicating that activity may be due to a critical phenomenon. Taken together, these results provide new insights into the design features of micro/nanomotors to ensure an efficient development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, B., Kostarelos, K., Nelson, B. J., & Zhang, L. (2021) · Advanced Materials · doi:10.1002/adma.202002047 · Cited by 497
Smart Materials for Microrobots
Soto, F., Karshalev, E., Zhang, F., Esteban Fernandez de Avila, B., Nourhani, A., & Wang, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00999 · Cited by 433
Enzyme-powered Janus platelet cell robots for active and targeted drug delivery
Tang, S., Zhang, F., Gong, H., Wei, F., Zhuang, J., Karshalev, E., Esteban-Fernández de Ávila, B., Huang, C., Zhou, Z., Li, Z., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aba6137 · Cited by 427
Targeting 3D Bladder Cancer Spheroids with Urease-Powered Nanomotors
Hortelão, A. C., Carrascosa, R., Murillo-Cremaes, N., Patiño, T., & Sánchez, S. (2019) · ACS Nano · doi:10.1021/acsnano.8b06610 · Cited by 287
Self-citationEnzyme-Powered Hollow Nanorobots for Active Microsampling Enabled by Thermoresponsive Polymer Gating
Liu, X., Chen, W., Zhao, D., Liu, X., Wang, Y., Chen, Y., & Ma, X. (2022) · ACS Nano · doi:10.1021/acsnano.2c00401 · Cited by 50
Engineered platelet cell motors for boosted cancer radiosensitization
Liu, W., Nie, H., Li, H., Liu, Y., Tian, M., Wang, S., Yang, Y., & Long, W. (2024) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.12.091 · Cited by 21
Metadata
- Authors
- Patiño, T., Feiner-Gracia, N., Arqué, X., Miguel-López, A., Jannasch, A., Stumpp, T., Schäffer, E., Albertazzi, L., & Sánchez, S.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-05-22
- Volume
- 140
- Issue
- 25
- Pages
- 7896-7903
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2803320903
- Cited by
- 231
- References
- 0
- FWCI
- 13.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.