Native Mass Spectrometry Imaging and In Situ Top-Down Identification of Intact Proteins Directly from Tissue
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Mass spectrometry imaging (MSI) provides information on the spatial distribution of molecules within a biological substrate without the requirement for labeling. Its broad specificity, i.e., the capability to spatially profile any analyte ion detected, constitutes a major advantage over other imaging techniques. A separate branch of mass spectrometry, native mass spectrometry, provides information relating to protein structure through retention of solution-phase interactions in the gas phase. Integration of MSI and native mass spectrometry ("native MSI") affords opportunities for simultaneous acquisition of spatial and structural information on proteins directly from their physiological environment. Here, we demonstrate significant improvements in native MSI and associated protein identification of intact proteins and protein assemblies in thin sections of rat kidney by use of liquid extraction surface analysis on a state-of-the-art Orbitrap mass spectrometer optimized for intact protein analysis. Proteins of up to 47 kDa, including a trimeric protein complex, were imaged and identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
Cited by
Warinner, C., Korzow Richter, K., & Collins, M. J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00703 · Cited by 178
Native Mass Spectrometry of Membrane Proteins
Keener, J. E., Zhang, G., & Marty, M. T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04342 · Cited by 126
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200721 · Cited by 54
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie · doi:10.1002/ange.202200721 · Cited by 6
Metadata
- Authors
- Hale, O. J., & Cooper, H. J.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-07-31
- Volume
- 31
- Issue
- 12
- Pages
- 2531-2537
- ISSN
- 1044-0305 (ISSN-L)
- 1879-1123
- OpenAlex
- W3046239096
- Cited by
- 29
- References
- 2
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.