The DOI matches its Crossref record.
Synthesis of Fluorinated Fluoresceins
Abstract
Several novel fluorinated fluoresceins (Oregon Green dyes) were prepared by the reaction of fluororesorcinols with phthalic anhydride and its derivatives. A novel regiospecific synthesis of fluororesorcinols was key to the successful synthesis of these new fluorophores. (Polyfluoro)nitrobenzenes were reacted with 2 equiv of sodium methoxide followed by reduction, hydrodediazoniation, and demethylation, giving the first straightforward synthesis of 2-fluororesorcinol, 4-fluororesorcinol, 2,4-difluororesorcinol, and 2,4,5-trifluororesorcinol. These fluorinated fluoresceins have higher photostability and ionize at a lower pH (p K a = 3.3−6.1) than fluorescein (p K a = 6.5). Some of the fluorinated fluoresceins have very high quantum yields (0.85−0.97), which, in combination with their lower p K a s and high photostability, makes them superior fluorescent dyes for use as reporter molecules in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent Indicators for Intracellular pH
Han, J., & Burgess, K. (2010) · Chemical Reviews · doi:10.1021/cr900249z · Cited by 1,620
Bright Ideas for Chemical Biology
Lavis, L. D., & Raines, R. T. (2008) · ACS Chemical Biology · doi:10.1021/cb700248m · Cited by 1,290
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Small-Molecule Fluorescent Sensors for Investigating Zinc Metalloneurochemistry
Nolan, E. M., & Lippard, S. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001409 · Cited by 620
Bright Building Blocks for Chemical Biology
Lavis, L. D., & Raines, R. T. (2014) · ACS Chemical Biology · doi:10.1021/cb500078u · Cited by 536
Nagano, T., & Yoshimura, T. (2002) · Chemical Reviews · doi:10.1021/cr010152s · Cited by 414
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Gee, K. R., Zhou, Z.-L., Qian, W.-J., & Kennedy, R. (2002) · Journal of the American Chemical Society · doi:10.1021/ja011774y · Cited by 406
Self-citationFluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media
De Acha, N., Elosúa, C., Corres, J., & Arregui, F. (2019) · Sensors · doi:10.3390/s19030599 · Cited by 294
Hu, J. J., Wong, N.-K., Ye, S., Chen, X., Lu, M.-Y., Zhao, A. Q., Guo, Y., Ma, A. C.-H., Leung, A. Y.-H., Shen, J., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b01881 · Cited by 279
Zhang, X., Chen, Y., He, H., Wang, S., Lei, Z., & Zhang, F. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202109728 · Cited by 176
Engineering coherence among excited states in synthetic heterodimer systems
Hayes, D., Griffin, G. B., & Engel, G. S. (2013) · Science · doi:10.1126/science.1233828 · Cited by 137
Maeda, H., Yamamoto, K., Kohno, I., Hafsi, L., Itoh, N., Nakagawa, S., Kanagawa, N., Suzuki, K., & Uno, T. (2007) · Chemistry – A European Journal · doi:10.1002/chem.200600522 · Cited by 85
Metadata
- Authors
- Sun, W.-C., Gee, K. R., Klaubert, D. H., & Haugland, R. P.
- Venue
- The Journal of Organic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 62
- Issue
- 19
- Pages
- 6469-6475
- ISSN
- 0022-3263 (ISSN-L)
- 1520-6904
- OpenAlex
- W2090878722
- Cited by
- 299
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.