A Statistical Kinetic Model for the Bulk Degradation of PLA-b-PEG-b-PLA Hydrogel Networks: Incorporating Network Non-Idealities
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Experimental studies and theoretical predictions of the bulk-degradation behavior of nonideal PLA- b -PEG- b -PLA hydrogels were performed. The theoretical predictions are based on a previously developed model to which refinements have been made, including the incorporation of a more realistic description of the cross-linked, copolymer network structure. Also, structural complexities such as unreacted vinyl groups, multiple degradation sites along the polymer chains, and distributions in the degrees of polymerization of the cross-links, cycles, and backbone chains that comprise the network are now included in the model. Each of these factors has a dramatic effect on the bulk-degradation behavior of the hydrogels, and this second generation model incorporates these factors into the theoretical description of the experimental system with only a minimal increase in the number of parameters and complexity of the model equations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Erosion kinetics of hydrolytically degradable polymers.
Tamada, J. A., & Langer, R. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.2.552 · Cited by 356
Chain-end scission in acid catalyzed hydrolysis of poly (d,l-lactide) in solution
Shih, C. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(94)00100-9 · Cited by 159
Shiaw-Guang Hu, D., & Liu, H.-J. (1993) · Polymer Bulletin · doi:10.1007/bf00300035 · Cited by 39
Cited by
Hydrogels in controlled release formulations: Network design and mathematical modeling
Lin, C.-C., & Metters, A. T. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.004 · Cited by 1,768
Self-citationCell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
PEG Hydrogels for the Controlled Release of Biomolecules in Regenerative Medicine
Lin, C.-C., & Anseth, K. S. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9801-2 · Cited by 1,063
Self-citationReview: Photopolymerizable and Degradable Biomaterials for Tissue Engineering Applications
Ifkovits, J. L., & Burdick, J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2007.0093 · Cited by 619
Metadata
- Authors
- Metters, A. T., Anseth, K. S., & Bowman, C. N.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-08-01
- Volume
- 105
- Issue
- 34
- Pages
- 8069-8076
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2055471521
- Cited by
- 113
- References
- 3
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.