Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine. 3. Measurements of Oxygen Concentration in Tissues and Biochemical Reactions
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A systematic investigation of the preparation, characterization, and use of lithium phthalocyanine (LiPc) microcrystalline powder as a probe for electron paramagnetic resonance (EPR) oximetry applications has recently been initiated (Ilangovan et al. J. Phys. Chem. B 2000, 104, 4047−4059). Electrochemical preparation of LiPc under potentiostatic conditions (+0.4 V) yielded microcrystalline paramagnetic particles that showed extremely narrow (<10 mG) and oxygen-dependent EPR line width measured at 9.82 GHz (Ilangovan et al. J. Phys. Chem. B 2000, 104, 9404−9410). In this report, we demonstrate the application of this material to measure oxygen concentration in a biochemical (xanthine/xanthine oxidase, X/XO), cellular (human polymorphonuclear neutrophils, PMNs), and in vivo (mice) biological systems. The microcrystalline particles showed high oxygen-sensitivity and stability in aqueous and physiological environments. The particles implanted in the gastrocnemius muscle of living mice were found to be stable enabling repetitive measurements of pO 2 for more than two weeks. Simultaneous measurements of oxygen consumption and oxygen radical generation from X/XO and activated PMNs systems were performed using a combination of the LiPc oximetry probe and DEPMPO spin-trap. The results demonstrated that the LiPc microcrystalline powder could provide accurate and repetitive measurements of oxygen in the medium of its dispersion or in any tissue region of pathophysiological interest.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Prior studies have suggested that it is simply related to the size of the particulate used, and to increase spectra strength, fine tuning of paramagnetic particulate size must be employed for the specific model under investigation [45, 54].”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [54]
In the citing paper
“Previous studies have identified that in biological tissues, a part of the oxygen sensitive LiPc form is converted into an oxygen-insensitive form [54].”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [54]
Citations
Cites
Frejaville, C., Karoui, H., Tuccio, B., Moigne, F. L., Culcasi, M., Pietri, S., Lauricella, R., & Tordo, P. (1995) · Journal of Medicinal Chemistry · doi:10.1021/jm00002a007 · Cited by 512
Eaton, G. R., Eaton, S. S., & Ohno, K. (2018) · CRC Press eBooks · doi:10.1201/9781351071888 · Cited by 305
The measurement of oxygen in vivo using EPR techniques
Swartz, H. M., & Clarkson, R. B. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/7/017 · Cited by 218
Oxymetry deep in tissues with low-frequency electron paramagnetic resonance.
Halpern, H. J., Yu, C., Peric, M., Barth, E., Grdina, D. J., & Teicher, B. A. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.26.13047 · Cited by 195
Roubaud, V., Sankarapandi, S., Kuppusamy, P., Tordo, P., & Zweier, J. L. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2067 · Cited by 186
Self-citationMagnetic-resonance studies in undoped trans-polyacetylene(CH)x. II
Nechtschein, M., Devreux, F., Genoud, F., Guglielmi, M., & Holczer, K. (1983) · Physical Review B · doi:10.1103/physrevb.27.61 · Cited by 160
Magnetic-resonance studies in undopedtrans-polyacetylene, (CH)x
Holczer, K., Boucher, J., Devreux, F., & Nechtschein, M. (1981) · Physical review. B, Condensed matter · doi:10.1103/physrevb.23.1051 · Cited by 149
In Vivo and in vitro EPR oximetry with fusinite: A new coal‐derived, particulate EPR probe
Vahidi, N., Clarkson, R. B., Liu, K. J., Norby, S. W., Wu, M., & Swartz, H. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310207 · Cited by 93
In vivo Oximetry Using EPR and India Ink
Goda, F., Liu, K. J., Walczak, T., O'Hara, J. A., Jiang, J., & Swartz, H. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330214 · Cited by 79
Roubaud, V., Sankarapandi, S., Kuppusamy, P., Tordo, P., & Zweier, J. L. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2542 · Cited by 72
Self-citation
Research works printed but not linked: 11
- Krishna M. C., 1998, Breast Dis., 10, 220
- Kuppusamy P., 1998, Cancer Res., 58, 1568
- Swartz H. M., 1998, Adv. Exp. Med. Biol., 454, 252
- Chen K., 1988, Biochim. Biophys. Acta, 943, 484
- Clarkson R. B., 1998, Phys. Med. Biol., 43, 1920
- Liu K. J., 1993, Proc. Natl. Acad. Sci. U.S.A., 90, 5442
- Liu K. J., 1995, Brain Res., 685, 98
- Ilangovan G., 2000, J. Phys. Chem. B, 104, 9410
- Ilangovan G., 2000, J. Phys. Chem. B, 104, 4059
- Fraticelli A., 1996, Biochim. Biophys. Acta, 1310, 259
- Gallez B., 1999, Magn. Reson. Med., 42, 196
Cited by
Theory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry
Ahmad, R., & Kuppusamy, P. (2010) · Chemical Reviews · doi:10.1021/cr900396q · Cited by 166
Self-citationNovel particulate spin probe for targeted determination of oxygen in cells and tissues
Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(03)00496-9 · Cited by 150
Self-citationLangan, L. M., Dodd, N. J. F., Owen, S. F., Purcell, W. M., Jackson, S. K., & Jha, A. N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149492 · Cited by 104
“Prior studies have suggested that it is simply related to the size of the particulate used, and to increase spectra strength, fine tuning of paramagnetic particulate size must be employed for the specific model under investigation [45, 54].”
Subramanian, S., Matsumoto, K., Mitchell, J. B., & Krishna, M. C. (2004) · NMR in Biomedicine · doi:10.1002/nbm.897 · Cited by 94
Ilangovan, G., Li, H., Zweier, J. L., Krishna, M. C., Mitchell, J. B., & Kuppusamy, P. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10254 · Cited by 84
Self-citation
Metadata
- Authors
- Ilangovan, G., Li, H., Zweier, J. L., & Kuppusamy, P.
- Affiliations
- Johns Hopkins University (US)
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-05-03
- Volume
- 105
- Issue
- 22
- Pages
- 5323-5330
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2026755199
- Cited by
- 51
- References
- 17
- Citations by year
- 2026: 1 · 2025: 2 · 2016: 2 · 2014: 2 · 2012: 2
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Journal of Physical Chemistry B (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Materials Science › Materials Chemistry › Porphyrin and Phthalocyanine Chemistry
- Keywords
- lithium phthalocyanine, EPR oximetry, oxygen concentration measurement, electrochemical synthesis, xanthine-xanthine oxidase system, neutrophils, oxygen consumption, oxygen free radicals, tissue oxygenation, gastrocnemius
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.