The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Mechanical and Transport Properties of the Poly(ethylene oxide)−Poly(acrylic acid) Double Network Hydrogel from Molecular Dynamic Simulations
Abstract
We used atomistic molecular dynamics (MD) simulations to investigate the mechanical and transport properties of the PEO-PAA double network (DN) hydrogel with 76 wt % water content. By analyzing the pair correlation functions for polymer-water pairs and for ion-water pairs and the solvent accessible surface area, we found that the solvation of polymer and ion in the DN hydrogel is enhanced in comparison with both PEO and PAA single network (SN) hydrogels. The effective mesh size of this DN hydrogel is smaller than that of the SN hydrogels with the same water content and the same molecular weight between the cross-linking points (Mc). Applying uniaxial extensions, we obtained the stress-strain curves for the hydrogels. This shows that the DN hydrogel has a sudden increase of stress above approximately 100% strain, much higher than the sum of the stresses of the two SN hydrogels at the same strain. This arises because PEO has a smaller Mc value than PAA, so that the PEO in the DN reaches fully stretched out at 100% strain that corresponds to 260% strain in the PEO SN (beyond this point, the bond stretching and the angle bending increase dramatically). We also calculated the diffusion coefficients of solutes such as D-glucose and ascorbic acid in the hydrogels, where we find that the diffusion coefficients of those solutes in the DN hydrogel are 60% of that in the PEO SN and 40% of that in the PAA SN due to its smaller effective mesh size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Physical Polymer Science
Sperling, L. H. (2005) · doi:10.1002/0471757128 · Cited by 2,917
Physicochemical Foundations and Structural Design of Hydrogels in Medicine and Biology
Peppas, N. A., Huang, Y., Torres-Lugo, M., Ward, J. H., & Zhang, J. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.9 · Cited by 1,016
Peppas, N. A. (1997) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(97)80103-3 · Cited by 454
Cited by
Why are double network hydrogels so tough?
Gong, J. P. (2010) · Soft Matter · doi:10.1039/b924290b · Cited by 2,328
Calvert, P. (2009) · Advanced Materials · doi:10.1002/adma.200800534 · Cited by 1,004
Super tough double network hydrogels and their application as biomaterials
Haque, M. A., Kurokawa, T., & Gong, J. P. (2012) · Polymer · doi:10.1016/j.polymer.2012.03.013 · Cited by 728
Fundamentals of double network hydrogels
Chen, Q., Chen, H., Zhu, L., & Zheng, J. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00123d · Cited by 657
Mechanical characterisation of hydrogel materials
Oyen, M. L. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000022 · Cited by 635
Metadata
- Authors
- Jang, S. S., Goddard, W. A., & Kalani, M. Y. S.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-01-24
- Volume
- 111
- Issue
- 7
- Pages
- 1729-1737
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2129082801
- Cited by
- 158
- References
- 3
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.