CoChat

Delay Time and Concentration Effects During Bioconjugation of Nanosecond Laser-Generated Nanoparticles in a Liquid Flow

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Fast ex situ functionalization of gold nanoparticles with fluorophore-labeled cell-penetrating peptides is investigated with a novel liquid flow cascade injection system. Successful conjugation is proved by various methods, such as UV−vis spectrometry and electron microscopy, whereas nanoparticle size-quenching is clearly observed. By variation of the peptide concentration introduced promptly after particle generation, gold nanoparticle bioconjugates with different degrees of cluster formation and/or aggregation and different peptide surface coverage values are obtained. The sizes of synthesized inorganic−organic gold nanoparticle bioconjugate show obvious correlation with time-delayed conjugation, giving evidence that laser-generated nanoparticles continue growing outside the cavitation bubble in the multisecond time scale until achieving their final size. Introducing 6.6 μM bioactive ligands, the highest conjugation efficiency of 93% and ζ potential of 27.5 mV is reached at the shortest delay time (200 ms), resulting in 20 nm average sized bioconjugates. Finally, in a preliminary biological application, laser scanning confocal microscopy clearly revealed an amplified cellular uptake using HIV-1 transactivator peptide-conjugated gold nanoparticles compared with nonconjugated entities within embryonic fibroblasts after a short coincubation time of 1 h. The generation of high amounts of highly pure cell-penetrating nanomarkers by the nanosecond laser-assisted fast ex situ conj…

Overview

Integrity signals

Registry

Crossref · 10.1021/jp1093405

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 44 references

Research works printed but not linked: 1

  1. Walter J. G., 2010, J. Nanobiotechnol., 8, 21, 10.1186/1477-3155-8-21 · DOI · Paper page

Cited by

Metadata

Authors
Sajti, C. L., Barchanski, A., Wagener, P., Klein, S., & Barcikowski, S.
Affiliations
  • Laser Zentrum Hannover (DE)
  • Insitute of Farm Animal Genetics, Höltystrasse 10, 31535 Neustadt, Germany
Corresponding author
Barcikowski, Stephan
Venue
The Journal of Physical Chemistry C
Published
2011-03-03
Volume
115
Issue
12
Pages
5094-5101
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2328821159
Cited by
33
References
44
Citations by year
2023: 2 · 2022: 3 · 2021: 2 · 2019: 2 · 2017: 3 · 2015: 3 · 2014: 5 · 2012: 13
FWCI
2.30
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Physical Chemistry C (publishedVersion)
  • OpenAgrar (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › Laser-Ablation Synthesis of Nanoparticles
  • Physical Sciences › Materials Science › Materials Chemistry › Nanocluster Synthesis and Applications
Keywords
gold nanoparticles, bioconjugation, nanosecond laser ablation, cell-penetrating peptides, nanoparticle aggregation, conjugation efficiency, zeta potential, cellular uptake

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.