CoChat

Methodological Improvement in Pulsed Laser-Induced Size Reduction of Aqueous Colloidal Gold Nanoparticles by Applying High Pressure

Werner, Daniel, Ueki, Tomoyuki, Hashimoto, Shuichi · 2012 · The Journal of Physical Chemistry C
Cited by 37

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

By applying high pressures well above the critical pressure of water (22.1 MPa), we prepared gold nanoparticles (Au NPs) using a nanosecond pulsed laser-induced size-reduction technique. The Au NPs thus obtained exhibited a narrow size distribution and size-selectivity dependent on the applied laser energy density (fluence). This is significant because previous attempts under ambient pressure failed to achieve such size-selective generation. Spherical Au NPs of diameters 46 and 33 nm, with a standard deviation of only 2–3 nm, were obtained at the expense of original faceted 58 nm Au NPs. We ascribed our results to the formation of a supercritical water layer surrounding the liquid droplet NP transformed by laser heating. The supercritical layer originates from heat transfer from the particle, leading to water temperatures above the critical point of 647 K. The supercritical water layer acts as an effective heat sink for photothermal layer-by-layer size reduction to release small fragments, leaving behind a core particle. The supercritical water can retard evaporation of atoms and clusters from the droplet, thus controlling the evaporation rate. In contrast, at an ambient pressure of 0.1 MPa, the size reduction takes place inside the bubble that can form through the explosive evaporation of superheated water. In this case, particles of various sizes were produced, accompanied by connected structures. This is because thermal insulation is achieved inside the bubble, where the size reduction takes place with insufficient cooling. This study clearly showed nanosecond laser-induced size reduction of Au NPs, better than that achieved previously, by introducing an additional parameter, pressure. This study provides a refined method for size control in laser ablation NP generation. We expect that a rich chemistry can proceed in this transient supercritical water layer surrounding the NP droplets as a reaction medium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp300690z

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Werner, D., Ueki, T., & Hashimoto, S.
Venue
The Journal of Physical Chemistry C
Published
2012-02-29
Volume
116
Issue
9
Pages
5482-5491
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W1991706886
Cited by
37
References
3
FWCI
3.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.