The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Extending Single-Molecule Microscopy Using Optical Fourier Processing
Open accessAbstract
This article surveys the recent application of optical Fourier processing to the long-established but still expanding field of single-molecule imaging and microscopy. A variety of single-molecule studies can benefit from the additional image information that can be obtained by modulating the Fourier, or pupil, plane of a widefield microscope. After briefly reviewing several current applications, we present a comprehensive and computationally efficient theoretical model for simulating single-molecule fluorescence as it propagates through an imaging system. Furthermore, we describe how phase/amplitude-modulating optics inserted in the imaging pathway may be modeled, especially at the Fourier plane. Finally, we discuss selected recent applications of Fourier processing methods to measure the orientation, depth, and rotational mobility of single fluorescent molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Shaping cups into phagosomes and macropinosomes
Swanson, J. A. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2447 · Cited by 941
Cited by
Organic Optoelectronic Materials: Mechanisms and Applications
Ostroverkhova, O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00127 · Cited by 1,680
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Self-citationOptimal Point Spread Function Design for 3D Imaging
Shechtman, Y., Sahl, S. J., Backer, A. S., & Moerner, W. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.133902 · Cited by 384
Self-citationDeepSTORM3D: dense 3D localization microscopy and PSF design by deep learning
Nehme, E., Freedman, D., Gordon, R., Ferdman, B., Weiss, L. E., Alalouf, O., Naor, T., Orange, R., Michaeli, T., & Shechtman, Y. (2020) · Nature Methods · doi:10.1038/s41592-020-0853-5 · Cited by 311
Metadata
- Authors
- Backer, A. S., & Moerner, W. E.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-05-12
- Volume
- 118
- Issue
- 28
- Pages
- 8313-8329
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2316685521
- Cited by
- 160
- References
- 2
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.