The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
ZnO Nanotube Arrays as Biosensors for Glucose
Abstract
Highly oriented single-crystal ZnO nanotube (ZNT) arrays were prepared by a two-step electrochemical/chemical process on indium-doped tin oxide (ITO) coated glass in an aqueous solution. The prepared ZNT arrays were further used as a working electrode to fabricate an enzyme-based glucose biosensor through immobilizing glucose oxidase in conjunction with a Nafion coating. The present ZNT arrays-based biosensor exhibits high sensitivity of 30.85 μA cm −2 mM −1 at an applied potential of +0.8 V vs. SCE, wide linear calibration ranges from 10 μM to 4.2 mM, and a low limit of detection (LOD) at 10 μM (measured) for sensing of glucose. The apparent Michaelis−Menten constant K M app was calculated to be 2.59 mM, indicating a higher bioactivity for the biosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
ZnO nanostructures: growth, properties and applications
Djurišić, A. B., Chen, X., Leung, Y. H., & Man Ching Ng, A. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15548f · Cited by 742
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Organic and inorganic nanomaterials: fabrication, properties and applications
Alshammari, B. H., Lashin, M. M. A., Mahmood, M. A., Al-Mubaddel, F. S., Ilyas, N., Rahman, N., Sohail, M., Khan, A., Abdullaev, S. S., & Khan, R. (2023) · RSC Advances · doi:10.1039/d3ra01421e · Cited by 331
EGFET-Based Sensors for Bioanalytical Applications: A Review
Pullano, S. A., Critello, C. D., Mahbub, I., Tasneem, N. T., Shamsir, S., Islam, S. K., Greco, M., & Fiorillo, A. S. (2018) · Sensors · doi:10.3390/s18114042 · Cited by 197
Metadata
- Authors
- Yang, K., She, G.-W., Wang, H., Ou, X.-M., Zhang, X.-H., Lee, C.-S., & Lee, S.-T.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-11-02
- Volume
- 113
- Issue
- 47
- Pages
- 20169-20172
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2012695022
- Cited by
- 202
- References
- 2
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ZnO Nanotube Arrays as Biosensors for Glucose. https://app.cochat.ai/papers/10.1021/jp901894j
- The paper
- Yang, K., She, G.-W., Wang, H., Ou, X.-M., Zhang, X.-H., Lee, C.-S., & Lee, S.-T. (2009). ZnO Nanotube Arrays as Biosensors for Glucose. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp901894j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.