The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Label-Free Photoelectrochemical Immunosensor Based on Water-Soluble CdS Quantum Dots
Abstract
We demonstrate herein a newly developed lable-free photoelectrochemical immunosensor using a CdS quantum dots (QDs) multilayer film coupled with a biospecific interaction. The CdS QDs multilayer film was prepared by layer-by-layer assembling positively charged poly(dimethyldiallylammonium chloride) (PDDA) and thioglycolic acid (TGA)-capped water-soluble CdS QDs with negative charges on the surface of an indium−tin oxide (ITO) electrode. Ascorbic acid (AA) was exploited as an efficient and nontoxic electron donor for scavenging photogenerated holes under mild solution medium. The photoexcitation of CdS QDs modified electrode potentiostated at 0 V (vs. Ag/AgCl) in the presence of 0.1 M AA led to a stable anodic photocurrent. To perform the immunoassay, goat antimouse IgG was conjugated onto CdS QDs modified electrode by using the classic EDC coupling reactions between COOH groups on the surfaces of the TGA capped CdS QDs and NH 2 groups of the antibody. The concentrations of mouse IgG were measured through the decrease in photocurrent intensity resulting from the increase in steric hindrances due to the formation of the immunocomplex. The synthetic conditions (different Cd/S ratio and different pH) of CdS QDs and the number of PDDA/CdS bilayers could influence the photoelectrochemical properties of CdS QDs modified electrodes used for immunosensor construction. Under the optimal conditions, a linear relationship between photocurrent decrease and mouse IgG concentration was obtained in the range of 10 pg/mL to 100 ng/mL with a detection limit of 8.0 pg/mL. This strategy opens a new perspective for the application of QDs, which might be of great significance for QDs in photoelectrochemical bioanalysis in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Signal Amplification by Allosteric Catalysis
Zhu, L., & Anslyn, E. V. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501476 · Cited by 151
Cited by
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Self-citationHildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Flexible supercapacitors based on paper substrates: a new paradigm for low-cost energy storage
Zhang, Y.-Z., Wang, Y., Cheng, T., Lai, W.-Y., Pang, H., & Huang, W. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00174a · Cited by 638
Metadata
- Authors
- Wang, G.-L., Yu, P.-P., Xu, J.-J., & Chen, H.-Y.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-02
- Volume
- 113
- Issue
- 25
- Pages
- 11142-11148
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2021440868
- Cited by
- 228
- References
- 2
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.