The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Hydrolysis of Tetrafluoroborate and Hexafluorophosphate Counter Ions in Imidazolium-Based Ionic Liquids
Abstract
Controversy behind the postulation that ionic liquids (ILs) are entirely green materials emerged a few years ago. This statement is not always valid, and properties such as toxicity and chemical/thermal stability of ILs should be fully characterized to evaluate their potential use as green solvents. Therefore, in this work, the thermal and chemical decompositions of hexafluorophosphate- and tetrafluoroborate-based ILs in aqueous solutions were evaluated. The experimental conditions employed allowed the study of the possible decomposition of both anions, the effect of the cation side alkyl chain length, the influence of the pH of the aqueous solutions, as well as the temperature influence. Three experimental techniques were employed to fully characterize those anions' stability, electrospray mass spectrometry, nuclear magnetic resonance spectroscopy, and pH measurements of the equilibrium aqueous solutions. The results noticeably indicate that it is suitable to use aqueous solutions of hexafluorophosphate-based ILs at moderate temperatures while acidic conditions promote the anion hydrolysis, even at low temperatures. On the other hand, the tetrafluoroborate-based ILs are not water-stable compounds since they hydrolyze under all of the conditions tested and the hydrolysis extent is markedly dependent on the temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huddleston, J. G., Visser, A. E., Reichert, W. M., Willauer, H. D., Broker, G. A., & Rogers, R. D. (2001) · Green Chemistry · doi:10.1039/b103275p · Cited by 3,712
Ionic liquids are not always green: hydrolysis of 1-butyl-3-methylimidazolium hexafluorophosphate
Swatloski, R. P., Holbrey, J. D., & Rogers, R. D. (2003) · Green Chemistry · doi:10.1039/b304400a · Cited by 982
Visser, A. E., Swatloski, R. P., Reichert, W. M., Griffin, S. T., & Rogers, R. D. (2000) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000426m · Cited by 640
Mutual Solubilities of Water and Hydrophobic Ionic Liquids
Freire, M. G., Neves, C. M. S. S., Carvalho, P. J., Gardas, R. L., Fernandes, A. M., Marrucho, I. M., Santos, L. M. N. B. F., & Coutinho, J. A. P. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp076271e · Cited by 411
Self-citationHydrolysis in the system LiPF6—propylene carbonate—dimethyl carbonate—H2O
Plakhotnyk, A. V., Ernst, L., & Schmutzler, R. (2005) · Journal of Fluorine Chemistry · doi:10.1016/j.jfluchem.2004.09.027 · Cited by 370
Mutual Solubilities of Water and the [Cnmim][Tf2N] Hydrophobic Ionic Liquids
Freire, M. G., Carvalho, P. J., Gardas, R. L., Marrucho, I. M., Santos, L. M. N. B. F., & Coutinho, J. A. P. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp7097203 · Cited by 358
Self-citationQuantification of Halide in Ionic Liquids Using Ion Chromatography
Villagrán, C., Deetlefs, M., Pitner, W. R., & Hardacre, C. (2004) · Analytical Chemistry · doi:10.1021/ac035157z · Cited by 241
Najdanovic-Visak, V., Esperança, J. M. S. S., Rebelo, L. P. N., Nunes da Ponte, M., Guedes, H. J. R., Seddon, K. R., & Szydlowski, J. (2002) · Physical Chemistry Chemical Physics · doi:10.1039/b201723g · Cited by 217
Archer, D. G., Widegren, J. A., Kirklin, D. R., & Magee, J. W. (2005) · Journal of Chemical & Engineering Data · doi:10.1021/je050136i · Cited by 72
Tseng, M., Liang, Y., & Chu, Y. (2005) · Tetrahedron Letters · doi:10.1016/j.tetlet.2005.06.153 · Cited by 63
Ponikvar‐Svet, M., Žemva, B., & Liebman, J. F. (2003) · Journal of Fluorine Chemistry · doi:10.1016/s0022-1139(03)00139-8 · Cited by 39
Lu, Y., King, F. L., & Duckworth, D. C. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.02.017 · Cited by 26
Cited by
Ventura, S. P. M., e Silva, F. A., Quental, M. V., Mondal, D., Freire, M. G., & Coutinho, J. A. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00550 · Cited by 1,024
Self-citationAqueous biphasic systems: a boost brought about by using ionic liquids
Freire, M. G., Cláudio, A. F. M., Araújo, J. M. M., Coutinho, J. A. P., Marrucho, I. M., Lopes, J. N. C., & Rebelo, L. P. N. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35151j · Cited by 817
Self-citationIonic Liquid Crystals: Versatile Materials
Goossens, K., Lava, K., Bielawski, C. W., & Binnemans, K. (2016) · Chemical Reviews · doi:10.1021/cr400334b · Cited by 780
Robust carbon dioxide reduction on molybdenum disulphide edges
Asadi, M., Kumar, B., Behranginia, A., Rosen, B. A., Baskin, A., Repnin, N., Pisasale, D., Phillips, P., Zhu, W., Haasch, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms5470 · Cited by 766
A non-flammable hydrous organic electrolyte for sustainable zinc batteries
Han, D., Cui, C., Zhang, K., Wang, Z., Gao, J., Guo, Y., Zhang, Z., Wu, S., Yin, L., Weng, Z., et al. (2021) · Nature Sustainability · doi:10.1038/s41893-021-00800-9 · Cited by 685
Metadata
- Authors
- Freire, M. G., Neves, C. M. S. S., Marrucho, I. M., Coutinho, J. A. P., & Fernandes, A. M.
- Venue
- The Journal of Physical Chemistry A
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-14
- Volume
- 114
- Issue
- 11
- Pages
- 3744-3749
- ISSN
- 1089-5639 (ISSN-L)
- 1520-5215
- OpenAlex
- W2052086659
- Cited by
- 662
- References
- 12
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.