Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 675

The DOI matches its Crossref record.

Poly(l-lysine)-g-Poly(ethylene glycol) Layers on Metal Oxide Surfaces: Attachment Mechanism and Effects of Polymer Architecture on Resistance to Protein Adsorption

Kenausis, Gregory L., Vörös, Janos, Elbert, Donald L., Huang, Ningping, Hofer, Rolf, Ruiz-Taylor, Laurence, Textor, Marcus, Hubbell, Jeffrey A., Spencer, Nicholas D.·2000·The Journal of Physical Chemistry B

Abstract

The generation of surfaces and interfaces that are able to withstand protein adsorption is a major challenge in the design of blood-contacting materials for both medical implants and bioaffinity sensors. Poly(ethylene glycol)-derived materials are generally considered to be particularly effective candidates for the fabrication of protein-resistant materials. Most metallic biomaterials are covered by a protective, stable oxide film; converting such oxide surfaces, which are known to strongly interact with proteins, into noninteractive surfaces requires a specific design of the surface/interface architecture. A class of copolymers based on poly( l -lysine)- g -poly(ethylene glycol) (PLL- g -PEG) was found to spontaneously adsorb from aqueous solutions onto several metal oxide surfaces, such as TiO 2, Si 0.4 Ti 0.6 O 2, and Nb 2 O 5, as measured by the in situ optical waveguide lightmode spectroscopy technique and by ex situ X-ray photoelectron spectroscopy. The resulting adsorbed layers are highly effective in reducing the adsorption both of blood serum and of individual proteins such as fibrinogen, which is known to play a major role in the cascade of events that lead to biomaterial-surface-induced blood coagulation and thrombosis. Adsorbed protein levels as low as <5 ng/cm 2 could be achieved for an optimized polymer architecture. The modified surfaces are stable to desorption under flow conditions at 37 °C and pH 7.4 in HEPES [4-(2-hydroxyethyl)piperazine-1-ethanesulfonic acid] and PBS (phosphate-buffered saline) buffers. The adsorbed layer of copolymer is thought to form a comblike structure at the surface, with positively charged primary amine groups of the PLL bound to the negatively charged metal oxide surface, while the hydrophilic and uncharged PEG side chains are exposed to the solution phase. Copolymer architecture is an important factor in the resulting protein resistance; it is discussed on the basis of packing-density considerations and the corresponding radii of gyration of the different PEG chain lengths studied. This surface functionalization technology is believed to be of value for use in both the biomaterial and biosensor areas, as the chosen macromolecules are biocompatible and the application is straightforward and cost-effective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp993359m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kenausis, G. L., Vörös, J., Elbert, D. L., Huang, N., Hofer, R., Ruiz-Taylor, L., Textor, M., Hubbell, J. A., & Spencer, N. D.
Venue
The Journal of Physical Chemistry B
Published
2000-03-15
Volume
104
Issue
14
Pages
3298-3309
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W1981028296
Cited by
675
References
0
FWCI
15.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.