CoChat

In Vitro Displacement by Rat Serum of Adsorbed Radiolabeled Poloxamer and Poloxamine Copolymers from Model and Biodegradable Nanospheres

Neal, Jonathan C., Stolnik, Snow, Schacht, Etienne, Kenawy, El Rafaie, Garnett, Martin C., Davis, Stanley S., Illum, Lisbeth · 1998 · Journal of Pharmaceutical Sciences
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Poloxamer 407 and poloxamine 908 have been used by many research groups to modify the surface of both model latex and biodegradable nanospheres, thereby producing nanospheres that have shown reduced protein adsorption in vitro and extended circulation times in vivo. A potential limitation of such systems is the desorption of the copolymer coating layer. We describe a two-stage process to radiolabel poloxamer 407 and poloxamine 908 that has facilitated an investigation into this potential desorption, in vitro. The first stage of the labeling procedure involved the substitution of the terminal hydroxyl groups in each poly(ethylene oxide) (PEO) chain of poloxamer 407 and poloxamine 908 with an amino group. The aminated copolymers were then radiolabeled with 125Iodine Bolton-Hunter reagent. The efficiency of labeling was calculated to be approximately 20% for the tetramine poloxamine 908 and approximately 33% for the diamine poloxamer 407. Remaining free amino groups were then either acetylated, using acetic anhydride, or left in the free amino form. Covalent linkage of the radiolabel to the copolymer was confirmed by nuclear magnetic resonance (NMR) and infrared (IR) spectroscopy. The stability of the link between radiolabel and copolymer to hydrolysis was also confirmed; <4% loss of radiolabel occurred from poloxamine 908 after incubation in phosphate-buffered saline (PBS) at 37 degrees C for 8 days. The radiolabeled copolymers (with the free amino groups acetylated) were then used in experiments that have given the first direct evidence that adsorbed copolymers can be displaced by serum proteins in significant amounts from the surface of model and biodegradable nanospheres. The displacement was highly dependent on copolymer-nanosphere compatibility, with up to 78% of 125I tetramine poloxamine 908 being displaced from poly(lactide-co-glycolide) (PLGA) nanospheres in 24 h, compared with 20% displacement of 125I tetramine poloxamine 908 in 24 h from polystyrene nanospheres. These results have direct implication for the future design of drug delivery systems based on coated nanospheres.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/js970462j

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Neal, J. C., Stolnik, S., Schacht, E., Kenawy, E. R., Garnett, M. C., Davis, S. S., & Illum, L.
Venue
Journal of Pharmaceutical Sciences
Published
1998-10
Volume
87
Issue
10
Pages
1242-1248
ISSN
0022-3549 (ISSN-L)
OpenAlex
W1969628438
Cited by
60
References
1
FWCI
3.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.