The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Poly(l-lysine)-g-poly(ethylene glycol) Layers on Metal Oxide Surfaces: Surface-Analytical Characterization and Resistance to Serum and Fibrinogen Adsorption
Abstract
Poly( l -lysine)- g -poly(ethylene glycol) (PLL- g -PEG) is a member of a family of polycationic PEG-grafted copolymers that have been shown to chemisorb on anionic surfaces, including various metal oxide surfaces, providing a high degree of resistance to protein adsorption. PLL- g -PEG-modified surfaces are attractive for a variety of applications including sensor chips for bioaffinity assays and blood-contacting biomedical devices. The analytical and structural properties of PLL- g -PEG adlayers on niobium oxide (Nb 2 O 5 ), tantalum oxide (Ta 2 O 5 ), and titanium oxide (TiO 2 ) surfaces were investigated using reflection−absorption infrared spectroscopy (RAIRS), angle-dependent X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The combined analytical information provides clear evidence for an architecture with the cationic poly( l -lysine) attached electrostatically to the oxide surfaces (charged negatively at physiological pH) and the poly(ethylene oxide) side chains extending out from the surface. The relative intensities of the vibrational modes in the RAIRS spectra and the angle-dependent XPS data point to the PLL backbone being located directly at and parallel to the oxide/polymer interface, whereas the PEG chains are preferentially oriented in the direction perpendicular to the surface. Both positive and negative ToF-SIMS spectra are dominated by PEG-related secondary ion fragments with strongly reduced metal (oxide) intensities pointing to an (almost) complete coverage by the densely packed PEG comblike grafts. The three different transition metal oxide surfaces with isoelectric points well below 7 were found to behave very similarly, both in respect to the kinetics of the polymer adlayer adsorption and properties as well as in terms of protein resistance of the PLL- g -PEG-modified surface. Adsorption of serum and fibrinogen was evaluated using the OWLS optical planar waveguide technique. The amount of human serum adsorbed on the modified surfaces was consistently below the detection limit of the optical sensor technique used (<1−2 ng cm - 2 ), and fibrinogen adsorption was reduced by 96−98% in comparison to the nonmodified (bare) oxide surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of X-Ray Photoelectron Spectroscopy
Moulder, J. F. (1995) · Medical Entomology and Zoology · Cited by 23,662
The Isoelectric Points of Solid Oxides, Solid Hydroxides, and Aqueous Hydroxo Complex Systems
Parks, G. A. (1965) · Chemical Reviews · doi:10.1021/cr60234a002 · Cited by 3,430
Introduction to infrared and Raman spectroscopy
Jayasooriya, U. A. (1991) · Spectrochimica Acta Part A: Molecular Spectroscopy · doi:10.1016/0584-8539(91)80026-f · Cited by 2,978
Harder, P., Grunze, M., Dahint, R., Whitesides, G. M., & Laibinis, P. E. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp972635z · Cited by 1,290
High resolution XPS of organic polymers: the scienta ESCA300 database
Pireaux, J. J. (1993) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(93)85006-7 · Cited by 851
Kenausis, G. L., Vörös, J., Elbert, D. L., Huang, N., Hofer, R., Ruiz-Taylor, L., Textor, M., Hubbell, J. A., & Spencer, N. D. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp993359m · Cited by 675
Self-citationBiodegradable hydrogels in drug delivery
Kamath, K. R., & Park, K. (1993) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(93)90027-2 · Cited by 539
Reduced thrombogenicity of polymers having phospholipid polar groups
Ishihara, K., Aragaki, R., Ueda, T., Watenabe, A., & Nakabayashi, N. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240809 · Cited by 394
Textor, M., Ruiz, L., Hofer, R., Rossi, A. M., Feldman, K., Hähner, G., & Spencer, N. D. (2000) · Langmuir · doi:10.1021/la990941t · Cited by 277
Self-citationReview of new experimental techniques for investigating random sequential adsorption
Ramsden, J. J. (1993) · Journal of Statistical Physics · doi:10.1007/bf01052813 · Cited by 219
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
FRET or No FRET: A Quantitative Comparison
Berney, C., & Danuser, G. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75126-1 · Cited by 652
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Chemical Strategies for Generating Protein Biochips
Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801711 · Cited by 590
In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins
Hucknall, A., Rangarajan, S., & Chilkoti, A. (2009) · Advanced Materials · doi:10.1002/adma.200900383 · Cited by 552
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Novel Strategies for the Prevention and Treatment of Biofilm Related Infections
Chen, M., Yu, Q., & Sun, H. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918488 · Cited by 429
Well-defined graft copolymers: from controlled synthesis to multipurpose applications
Feng, C., Li, Y., Yang, D., Hu, J., Zhang, X., & Huang, X. (2011) · Chem. Soc. Rev. · doi:10.1039/b921358a · Cited by 426
Harris, L. G., Tosatti, S., Wieland, M., Textor, M., & Richards, R. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.033 · Cited by 393
Self-citationProteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Staphylococci and implant surfaces: a review
Harris, L. G., & Richards, R. G. (2006) · Injury · doi:10.1016/j.injury.2006.04.003 · Cited by 385
Tethered polymer chains: surface chemistry and their impact on colloidal and surface properties
Currie, E. P. K., Norde, W., & Cohen Stuart, M. A. (2003) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(02)00061-1 · Cited by 382
The mechanisms and dynamics of αvβ3 integrin clustering in living cells
Cluzel, C., Saltel, F., Lussi, J., Paulhe, F., Imhof, B. A., & Wehrle-Haller, B. (2005) · The Journal of Cell Biology · doi:10.1083/jcb.200503017 · Cited by 351
Polyelectrolyte adsorption, interparticle forces, and colloidal aggregation
Szilagyi, I., Trefalt, G., Tiraferri, A., Maroni, P., & Borkovec, M. (2014) · Soft Matter · doi:10.1039/c3sm52132j · Cited by 343
Pursuing “Zero” Protein Adsorption of Poly(carboxybetaine) from Undiluted Blood Serum and Plasma
Yang, W., Xue, H., Li, W., Zhang, J., & Jiang, S. (2009) · Langmuir · doi:10.1021/la9015788 · Cited by 305
Blood compatible materials: state of the art
Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00881b · Cited by 288
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Solid supports for microarray immunoassays
Kusnezow, W., & Hoheisel, J. D. (2003) · Journal of Molecular Recognition · doi:10.1002/jmr.625 · Cited by 277
Cai, K., Frant, M., Bossert, J., Hildebrand, G., Liefeith, K., & Jandt, K. D. (2006) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2006.03.016 · Cited by 274
Flexible phenylalanine-glycine nucleoporins as entropic barriers to nucleocytoplasmic transport
Lim, R. Y. H., Huang, N.-P., Köser, J., Deng, J., Lau, K. H. A., Schwarz-Herion, K., Fahrenkrog, B., & Aebi, U. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603521103 · Cited by 273
Self-citationSurface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Boulmedais, F., Frisch, B., Etienne, O., Lavalle, P., Picart, C., Ogier, J., Voegel, J.-C., Schaaf, P., & Egles, C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.039 · Cited by 259
Yang, W., Chen, S., Cheng, G., Vaisocherová, H., Xue, H., Li, W., Zhang, J., & Jiang, S. (2008) · Langmuir · doi:10.1021/la801487f · Cited by 258
Tsai, W.-B., Chien, C.-Y., Thissen, H., & Lai, J.-Y. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.010 · Cited by 108
Wattendorf, U., Coullerez, G., Vörös, J., Textor, M., & Merkle, H. P. (2008) · Langmuir · doi:10.1021/la801085d · Cited by 58
Self-citation
Metadata
- Authors
- Huang, N.-P., Michel, R., Voros, J., Textor, M., Hofer, R., Rossi, A., Elbert, D. L., Hubbell, J. A., & Spencer, N. D.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-21
- Volume
- 17
- Issue
- 2
- Pages
- 489-498
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2045691265
- Cited by
- 479
- References
- 14
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.