The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Abstract
This paper describes the use of surface plasmon resonance spectroscopy and self-assembled monolayers (SAMs) of alkanethiols on gold to evaluate the ability of surfaces terminating in different combinations of charged groups to resist the nonspecific adsorption of proteins from aqueous buffer. Mixed SAMs formed from a 1:1 combination of a thiol terminated in a trimethylammonium group and a thiol terminated in a sulfonate group adsorbed less than 1% of a monolayer of two proteins with different characteristics: fibrinogen and lysozyme. Single-component SAMs formed from thiols terminating in groups combining a positively charged moiety and a negatively charged moiety were also capable of resisting the adsorption of proteins. Single-component SAMs presenting single charges adsorbed nearly a full monolayer of protein. The amount of protein that adsorbed to mixed zwitterionic SAMs did not depend on the ionic strength or the pH of the buffer in which the protein was dissolved. The amount of protein that adsorbed to single-component zwitterionic SAMs increased as the ionic strength of the buffer decreased; it also decreased as the pH of the buffer increased (at constant ionic strength). Single-component zwitterionic SAMs composed of thiols terminating in N,N -dimethyl-amino-propane-1-sulfonic acid (−N + (CH 3 ) 2 CH 2 CH 2 CH 2 SO 3 - ) groups were substantially more effective at resisting adsorption of fibrinogen and lysozyme from buffer at physiological ionic strength and pH than single-component zwitterionic SAMs composed of thiols terminating in phosphoric acid 2-trimethylamino-ethyl ester (−OP(O) 2 - OCH 2 CH 2 N + (CH 3 ) 3 ). Several of these zwitterionic SAMs were comparable to the best known systems for resisting nonspecific adsorption of protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luk, Y.-Y., Kato, M., & Mrksich, M. (2000) · Langmuir · doi:10.1021/la0004653 · Cited by 414
Kumler, W. D., & Eiler, J. J. (1943) · Journal of the American Chemical Society · doi:10.1021/ja01252a028 · Cited by 274
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Hydrogels in regenerative medicine
Slaughter, B. V., Khurshid, S. S., Fisher, O. Z., Khademhosseini, A., & Peppas, N. A. (2009) · Advanced Materials · doi:10.1002/adma.200802106 · Cited by 2,703
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Self-citationSurface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Surface Modification of Water Purification Membranes
Miller, D. J., Dreyer, D. R., Bielawski, C. W., Paul, D. R., & Freeman, B. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201601509 · Cited by 747
Metadata
- Authors
- Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-06
- Volume
- 17
- Issue
- 9
- Pages
- 2841-2850
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2079347827
- Cited by
- 891
- References
- 2
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.