Multivariate Surface Analysis of Plasma-Deposited Tetraglyme for Reduction of Protein Adsorption and Monocyte Adhesion
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Adsorbed proteins on implanted biomedical devices mediate platelet and leukocyte adhesion. Radio frequency plasma deposited tetraglyme (CH 3 O(CH 2 CH 2 O) 4 CH 3 ), which forms a PEO-like coating, has been shown to resist protein adsorption and monocyte adhesion in vitro. By using different plasma deposition powers (5−80 W), we produced a series of plasma-deposited tetraglyme surfaces that varied in surface chemistry as measured by electron spectroscopy for chemical analysis (ESCA) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Both fibrinogen and IgG adsorption were increased on surfaces made at high plasma power. Monocyte adhesion correlated linearly with the amount of adsorbed protein. To identify the surface chemical features that contributed to the nonfouling properties of plasma-deposited tetraglyme, multivariate analysis using partial least squares (PLS) regression was applied. A PLS calibration model based on deposited tetraglyme samples placed downstream in the plasma reactor successfully predicted fibrinogen adsorption to deposited tetraglyme samples placed midstream in the reactor. The model identified how each surface spectral variable from ESCA and ToF-SIMS contributed to protein adsorption. The fraction of carbon in ether carbon linkages as measured by ESCA and ToF-SIMS peaks at m / z 59 and 103 was higher on surfaces that exhibited ultralow fibrinogen adsorption (<10 ng/cm 2 ). The fraction of hydrocarbon-like carbons as measured by ESCA and low-mass ToF-SIMS peaks such as m / z 29 and 31 was greater on surfaces exhibiting high fibrinogen adsorption (>200 ng/cm 2 ). This study elucidated the surface chemical features of deposited tetraglyme that most affect its resistance to protein and cell uptake and provided guidelines for engineering improved nonfouling biomaterial surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Cited by
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
A BioMEMS Review: MEMS Technology for Physiologically Integrated Devices
Grayson, A. C. R., Shawgo, R. S., Johnson, A. M., Flynn, N. T., Li, Y., Cima, M. J., & Langer, R. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820534 · Cited by 562
Zhang, Z., Chen, S., Chang, Y., & Jiang, S. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057266i · Cited by 539
Feng, W., Zhu, S., Ishihara, K., & Brash, J. L. (2005) · Langmuir · doi:10.1021/la050277i · Cited by 367
Chang, Y., Chang, W.-J., Shih, Y.-J., Wei, T.-C., & Hsiue, G.-H. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200055k · Cited by 325
Zhao, C., Li, L., & Zheng, J. (2010) · Langmuir · doi:10.1021/la103382j · Cited by 100
Wang, L., Li, H., Chen, S., Nie, C., Cheng, C., & Zhao, C. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00320 · Cited by 33
Metadata
- Authors
- Shen, M., Wagner, M. S., Castner, D. G., Ratner, B. D., & Horbett, T. A.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-11
- Volume
- 19
- Issue
- 5
- Pages
- 1692-1699
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2049059816
- Cited by
- 141
- References
- 1
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.