The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Endothelial Cell Traction Forces on RGD-Derivatized Polyacrylamide Substrata
Abstract
Receptor-mediated adhesion involves both mechanical and chemical signals occurring at the cell−substrate interface. Using a relatively new technique called traction force microscopy, the magnitude, direction, and spatial location of mechanical forces exerted by endothelial cells on a RGD-peptide-derivatized hydrogel substrate were measured. We constructed a surface with a controlled density of cell adhesion nonapeptide containing RGD, which can ligate endothelial cell integrin receptors and induce cell spreading. Increasing the concentration of the RGD peptide increases cell spreading on an otherwise nonadhesive surface of polyacrylamide, and cell area is a monotonically increasing function of peptide concentration. Correlating the force exerted by the cell to the cell area reveals that force is a linear, increasing function of cell area, with a mean increase in cell force of 10 4 dyn/cm 2 cell area. Additionally, we have found that tractions exerted by endothelial cells are concentrated at the ends of pseudopodia and are almost negligible under the nucleus. These results indicate that endothelial cells may have an internal structure that contacts and pulls on the substrate at concentrated locations within the tips of cell extensions and that the strength in adhesion increases with cell spreading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Migration: A Physically Integrated Molecular Process
Lauffenburger, D. A., & Horwitz, A. F. (1996) · Cell · doi:10.1016/s0092-8674(00)81280-5 · Cited by 3,915
Cited by
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941
Self-citationA Review of Cell Adhesion Studies for Biomedical and Biological Applications
Khalili, A., & Ahmad, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160818149 · Cited by 951
Rheological properties of peptide-based hydrogels for biomedical and other applications
Yan, C., & Pochan, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b919449p · Cited by 800
Cell-Cell Mechanical Communication through Compliant Substrates
Reinhart-King, C. A., Dembo, M., & Hammer, D. A. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.127662 · Cited by 390
Self-citationWiner, J. P., Oake, S., & Janmey, P. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006382 · Cited by 368
Metadata
- Authors
- Reinhart-King, C. A., Dembo, M., & Hammer, D. A.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-12-18
- Volume
- 19
- Issue
- 5
- Pages
- 1573-1579
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2168690340
- Cited by
- 185
- References
- 1
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endothelial Cell Traction Forces on RGD-Derivatized Polyacrylamide Substrata. https://app.cochat.ai/papers/10.1021/la026142j
- The paper
- Reinhart-King, C. A., Dembo, M., & Hammer, D. A. (2003). Endothelial Cell Traction Forces on RGD-Derivatized Polyacrylamide Substrata. Langmuir. https://doi.org/10.1021/la026142j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.