The DOI matches its Crossref record.
Evaluation of the Stability of Nonfouling Ultrathin Poly(ethylene glycol) Films for Silicon-Based Microdevices
Abstract
The creation of nonfouling surfaces is one of the major prerequisites for microdevices for biomedical and analytical applications. Poly(ethylene glycol) (PEG), a water soluble, nontoxic, and nonimmunogenic polymer has the unique ability of reducing nonspecific protein adsorption and cell adhesion and, therefore, is generally coupled with a wide variety of surfaces to improve their biocompatibility. The performance of these modified surfaces for long-term biomedical applications largely depends on the stability of these PEG films. To this end, we have investigated the stability of covalently coupled ultrathin PEG films on silicon in aqueous in vivo like conditions for a period of 4 weeks. The PEG-modified silicon substrates were incubated in PBS (37 degrees C, pH 7.4, 5% CO2) for different periods of time and then characterized using the techniques of ellipsometry, contact angle measurement, X-ray photoelectron spectroscopy, and atomic force microscopy. The ability of the PEG-modified surfaces to control protein fouling was examined by protein adsorption studies using fluorescein isothiocyanate labeled bovine serum albumin and ellipsometry. Furthermore, the ability of these films to control fibroblast adhesion was examined. Studies suggest that the PEG-modified surfaces retain their protein and cell repulsive nature even though the PEG film thickness decreases for the period of investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomedicine—Challenge and Perspectives
Riehemann, K., Schneider, S. W., Luger, T. A., Godin, B., Ferrari, M., & Fuchs, H. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200802585 · Cited by 1,305
Advances in polymers for anti-biofouling surfaces
Krishnan, S., Weinman, C. J., & Ober, C. K. (2008) · Journal of Materials Chemistry · doi:10.1039/b801491d · Cited by 824
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
3D Cell Culture: A Review of Current Approaches and Techniques
Haycock, J. W. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-60761-984-0_1 · Cited by 534
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Comparative stability studies of poly(2-methyl-2-oxazoline) and poly(ethylene glycol) brush coatings
Pidhatika, B., Rodenstein, M., Chen, Y., Rakhmatullina, E., Mühlebach, A., Acikgöz, C., Textor, M., & Konradi, R. (2012) · Biointerphases · doi:10.1007/s13758-011-0001-y · Cited by 251
Surface functionalization of biomaterials by radical polymerization
Zhou, T., Zhu, Y., Li, X., Liu, X., Yeung, K. W. K., Wu, S., Wang, X., Cui, Z., Yang, X., & Chu, P. K. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2016.04.005 · Cited by 145
Liu, Q., Chiu, A., Wang, L., An, D., Li, W., Chen, E. Y., Zhang, Y., Pardo, Y., McDonough, S. P., Liu, L., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119640 · Cited by 120
Metadata
- Authors
- Sharma, S., Johnson, R. W., & Desai, T. A.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-20
- Volume
- 20
- Issue
- 2
- Pages
- 348-356
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2057393780
- Cited by
- 197
- References
- 0
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.