Physicochemical Characterization of Degradable Thermosensitive Polymeric Micelles
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Amphiphilic AB block copolymers consisting of thermosensitive poly(N-(2-hydroxypropyl) methacrylamide lactate) and poly(ethylene glycol), pHPMAmDL-b-PEG, were synthesized via a macroinitiator route. Dynamic light scattering measurements showed that these block copolymers form polymeric micelles in water with a size of around 50 nm by heating of an aqueous polymer solution from below to above the critical micelle temperature (cmt). The critical micelle concentration as well as the cmt decreased with increasing pHPMAmDL block lengths, which can be attributed to the greater hydrophobicity of the thermosensitive block with increasing molecular weight. Cryogenic transmission electron microscopy analysis revealed that the micelles have a spherical shape with a narrow size distribution. 1H NMR measurements in D2O showed that the intensity of the peaks of the protons from the pHPMAmDL block significantly decreased above the cmt, indicating that the thermosensitive blocks indeed form the solidlike core of the micelles. Static light scattering measurements demonstrated that pHPMAmDL-b-PEG micelles with relatively large pHPMAmDL blocks possess a highly packed core that is stabilized by a dense layer of swollen PEG chains. FT-IR analysis indicated that dehydration of amide bonds in the pHPMAmDL block occurs when the polymer dissolved in water is heated from below to above its cmt. The micelles were stable when an aqueous solution of micelles was incubated at 37 degrees C and at pH 5.0, where the hydrolysis rate of lactate side groups is minimized. On the other hand, at pH 9.0, where hydrolysis of the lactic acid side groups occurs, the micelles started to swell after 1.5 h of incubation and complete dissolution of micelles was observed after 4 h as a result of hydrophilization of the thermosensitive block. Fluorescence spectroscopy measurements with pyrene loaded in the hydrophobic core of the micelles showed that when these micelles were incubated at pH 8.6 and at 37 degrees C the microenvironment of pyrene became increasingly hydrated in time during this swelling phase. The results demonstrate the potential applicability of pHPMAmDL-b-PEG block copolymer micelles for the controlled delivery of hydrophobic drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
Block copolymer micelles for drug delivery: design, characterization and biological significance
Kataoka, K., Harada, A., & Nagasaki, Y. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00124-1 · Cited by 3,506
Pluronic® block copolymers as novel polymer therapeutics for drug and gene delivery
Kabanov, A. V., Batrakova, E. V., & Alakhov, V. Y. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00009-3 · Cited by 1,474
Polymeric micelles—A new generation of colloidal drug carriers
Jones, M.-C., & Leroux, J.-C. (1999) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(99)00039-9 · Cited by 1,256
Micelles based on AB block copolymers of poly (ethylene oxide) and poly (beta.-benzyl L-aspartate)
Kwon, G., Naito, M., Yokoyama, M., Okano, T., Sakurai, Y., & Kataoka, K. (1993) · Langmuir · doi:10.1021/la00028a012 · Cited by 399
Yokoyama, M. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(97)00115-6 · Cited by 308
Liggins, R. T., & Burt, H. M. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00016-9 · Cited by 286
Cited by
Block copolymer micelles: preparation, characterization and application in drug delivery
Gaucher, G., Dufresne, M.-H., Sant, V. P., Kang, N., Maysinger, D., & Leroux, J.-C. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.09.034 · Cited by 1,498
Polymeric Micelles in Anticancer Therapy: Targeting, Imaging and Triggered Release
Oerlemans, C., Bult, W., Bos, M., Storm, G., Nijsen, J. F. W., & Hennink, W. E. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0233-4 · Cited by 947
Self-citationRijcken, C. J. F., Soga, O., Hennink, W. E., & Nostrum, C. F. V. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.03.023 · Cited by 487
Self-citationThermosensitive and biodegradable polymeric micelles for paclitaxel delivery
Soga, O., van Nostrum, C. F., Fens, M., Rijcken, C. J. F., Schiffelers, R. M., Storm, G., & Hennink, W. E. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.12.009 · Cited by 319
Rijcken, C. J., Snel, C. J., Schiffelers, R. M., van Nostrum, C. F., & Hennink, W. E. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.047 · Cited by 278
Self-citationCore-crosslinked polymeric micelles with controlled release of covalently entrapped doxorubicin
Talelli, M., Iman, M., Varkouhi, A. K., Rijcken, C. J. F., Schiffelers, R. M., Etrych, T., Ulbrich, K., van Nostrum, C. F., Lammers, T., Storm, G., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.07.005 · Cited by 267
Self-citationPolymeric micelles: authoritative aspects for drug delivery
Kulthe, S. S., Choudhari, Y. M., Inamdar, N. N., & Mourya, V. (2012) · Designed Monomers and Polymers · doi:10.1080/1385772x.2012.688328 · Cited by 235
“With an increase in hydrophobic block length the CMC as well as the CMT decreased, which can be attributed to the greater hydrophobicity of the thermosensitive block with increasing molecular weight [144].”
BackgroundShi, Y., van Steenbergen, M. J., Teunissen, E. A., Novo, L., Gradmann, S., Baldus, M., van Nostrum, C. F., & Hennink, W. E. (2013) · Biomacromolecules · doi:10.1021/bm400234c · Cited by 222
Self-citationTalelli, M., Rijcken, C. J. F., Lammers, T., Seevinck, P. R., Storm, G., van Nostrum, C. F., & Hennink, W. E. (2009) · Langmuir · doi:10.1021/la8036499 · Cited by 210
Self-citationRecent Advances in Nanomicelles Delivery Systems.
Tawfik, S. M., Azizov, S., Elmasry, M. R., Sharipov, M., & Lee, Y.-I. (2020) · Nanomaterials · doi:10.3390/nano11010070 · Cited by 156
Biotin-decorated all-HPMA polymeric micelles for paclitaxel delivery
Wang, Y., van Steenbergen, M. J., Beztsinna, N., Shi, Y., Lammers, T., van Nostrum, C. F., & Hennink, W. E. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.09.013 · Cited by 66
Self-citationvan Hasselt, P. M., Janssens, G. E. P. J., Slot, T. K., van der Ham, M., Minderhoud, T. C., Talelli, M., Akkermans, L. M., Rijcken, C. J. F., & van Nostrum, C. F. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.09.089 · Cited by 60
Self-citation
Metadata
- Authors
- Soga, O., van Nostrum, C. F., Ramzi, A., Visser, T., Soulimani, F., Frederik, P. M., Bomans, P. H. H., & Hennink, W. E.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-09-16
- Volume
- 20
- Issue
- 21
- Pages
- 9388-9395
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2082316779
- Cited by
- 143
- References
- 7
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.