Cell Adhesion on Nanofibrous Polytetrafluoroethylene (nPTFE)
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Here, we described the in vitro biocompatibility of a novel nanostructured surface composed of PTFE as a potential polymer for the prevention of adverse host reactions to implanted devices. The foreign body response is characterized at the tissue-material interface by several layers of macrophages and large multinucleated cells known as foreign body giant cells (FBGC), and a fibrous capsule. The nanofibers of nanofibrous PTFE (nPTFE) range in size from 20 to 30 nm in width and 3-4 mm in length. Glass surfaces coated with nPTFE (produced by jet-blowing of PTFE 601A) were tested under in vitro conditions to characterize the amount of protein adsorption, cell adhesion, and cell viability. We have shown that nPTFE adsorbs 495 +/- 100 ng of bovine serum albumin (BSA) per cm2. This level was considerably higher than planar PTFE, most likely due to the increase in hydrophobicity and available surface area, both a result of the nanoarchitecture. Endothelial cells and macrophages were used to determine the degree of cell adsorption on the surface of the nanostructured polymer. Both cell types were significantly more round and occupied less area on nPTFE as compared to tissue culture polystyrene (TCPS). Furthermore, a larger majority of the cells on the nPTFE were dead compared to TCPS, at dead-to-live ratios of 778 +/- 271 to 1 and 23 +/- 5.6 to 1, respectively. Since there was a high amount of cell death (due to either apoptosis or necrosis), and the foreign body response is a form of chronic inflammation, an 18 cytokine Luminex panel was performed on the supernatant from macrophages adherent on nPTFE and TCPS. As a positive control for inflammation, lipopolysaccharide (LPS) was added to macrophages on TCPS to estimate the maximum inflammation response of the macrophages. From the data presented with respect to IL-1, TNF-alpha, IFN-gamma, and IL-5, we concluded that nPTFE is nonimmunogenic and should not yield a huge inflammatory response in vivo, and cell death observed on the surface of nPTFE was likely due to apoptosis resulting from the inability of cells to spread on these surface. On the basis of the production of IL-1, IL-6, IL-4, and GM-CSF, we concluded that FBGC formation on nPTFE may be decreased as compared to materials known to elicit FBGC formation in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Refai, A. K., Textor, M., Brunette, D. M., & Waterfield, J. D. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30075 · Cited by 296
Gollwitzer, H., Thomas, P., Diehl, P., Steinhauser, E., Summer, B., Barnstorf, S., Gerdesmeyer, L., Mittelmeier, W., & Stemberger, A. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2005.02.003 · Cited by 67
Cited by
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Bernard, M., Jubeli, E., Pungente, M. D., & Yagoubi, N. (2018) · Biomaterials Science · doi:10.1039/c8bm00518d · Cited by 350
Wang, D., Xu, Y., Li, Q., & Turng, L.-S. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb01849b · Cited by 171
Chamberlain, L. M., Godek, M. L., Gonzalez‐Juarrero, M., & Grainger, D. W. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31930 · Cited by 112
Battiston, K. G., McBane, J. E., Labow, R. S., & Paul Santerre, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.015 · Cited by 25
Metadata
- Authors
- Ainslie, K. M., Bachelder, E. M., Borkar, S., Zahr, A. S., Sen, A., Badding, J. V., & Pishko, M. V.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-19
- Volume
- 23
- Issue
- 2
- Pages
- 747-754
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2059885593
- Cited by
- 43
- References
- 2
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.