CoChat

Zeta Potential of Ion-Conductive Membranes by Streaming Current Measurements

Xie, He, Saito, Tomonori, Hickner, Michael A. · 2011 · Langmuir
Cited by 105

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Surface charge properties have a significant influence on membrane retention and fouling performance. As a key parameter describing the surface charge of membranes used in aqueous applications, zeta potential measurements on membranes of various types have attracted great attention. During the zeta potential characterization of a series of ion-conductive sulfonated poly(sulfone) membranes, it was found that the measured streaming current varied with the thickness of the sample, which is not predicted by the classical Smoluchowski equation. Moreover, for higher conductivity membranes with an increased concentration of sulfonate groups, the zeta potential tended toward zero. It was determined that the influence of membrane bulk conductance on the measured streaming current must be taken into account in order to correctly interpret the streaming current data for ion-conductive polymers and understand the relationship between membrane chemical composition and zeta potential. Extrapolating the measured streaming current to a membrane thickness of zero has proven to be a feasible method of eliminating the error associated with measuring the zeta potential on ion conductive polymer membranes. A linear resistance model is proposed to account for the observed streaming currents where the electrolyte channel is in parallel with the ion-conductive membranes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la105120f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 105

Metadata

Authors
Xie, H., Saito, T., & Hickner, M. A.
Venue
Langmuir
Published
2011-03-28
Volume
27
Issue
8
Pages
4721-4727
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2323814078
Cited by
105
References
1
FWCI
3.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.